There are over 4392 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Auto Report Battery Time | 0 to 127 (Default) |
The interval time for auto report the battery level. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Auto Report Temperature Time | 0 to 127 (Default) |
The interval time for auto report the temperature. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | Auto Report Humidity Time | 0 to 127 (Default) |
The interval time for auto report the humidity. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Auto Report Tick Interval | 0 to 255 (Default) |
The interval time for auto report each tick. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Temperature Differential Report | 0 to 127 (Default) |
The temperature differential to report. 0 means turn off this function. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
23 | 1 | Humidity Differential Report | 0 to 60 (Default) |
The humidity differential to report. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Operation Mode | 8 | Setting the temperature scale. 0: Fahrenheit, 1:Celsius | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Customer Function | 32 | Disable Multi CC in auto report. (1:Disable, 0:Enable) | |
16 | Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report. | ||||