Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: FIBARO Flood Sensor (FGFS-101)

Z-Wave Certification Number: ZC10-15080018


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 2 Alarm cancellation delay 0 to 3600
(Default)
in seconds, each 1s

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 4 Temperature measurement interval 1 to 65535
(Default)
in seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 2 Temperature measurement hysteresis 1 to 1000
(Default)
each 0.01

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Acoustic and visual signals On/Off in case of flooding 0 acoustic and visual alarms inactive
  1 acoustic alarm inactive, visual alarm active
  2 acoustic alarm active, visual alarm inactive
  3
(Default)
acoustic and visual alarms active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

50 2 Low temperature alarm threshold -10000 to 10000
(Default)
each 0.01

Parameter Number

Parameter Size

Parameter Name

Parameter Values

51 2 High temperature alarm threshold -10000 to 10000
(Default)
each 0.01

Parameter Number

Parameter Size

Parameter Name

Parameter Values

61 4 Low temperature alarm indicator colour 0 to 16777215
(Default)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

62 4 High temperature alarm indicator colour 0 to 16777215
(Default)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

63 1 Managing a visual indicator under standard operation 0 Visual indicator does not indicate the temperature
  1 Visual indicator indicates the temperature (blink) every Temperature Measurement Interval (Parameter 10, constant current and battery) or Wake Up Interval (battery mode)
  2
(Default)
Visual indicator indicates the temperature continuously, only in constant power mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 2 Forced dimming level / roller blind opening level, when sending turn on / open command to 2nd association group devices 1 to 99 forced level
  255
(Default)
turn a device on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

73 2 Temperature measurement compensation -10000 to 10000
(Default)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

74 1 Alarm frame sent to 1st and 4th Association Group activation (MOVEMENT_TAMPER / BUTTON_TAMPER) 0 tamper alarms inactive
  1 button tamper alarm active
  2
(Default)
button tamper alarm active
  3 button and movement tampers alarm active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

75 4 Visual and audible alarms duration 0
(Default)
alarms active indefinitely
  1 to 65535 time in seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

76 4 Alarm frame / Basic Set frame retransmission time when retaining flood alarm 0
(Default)
retransmission inactive
  1 to 65535 time in seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

77 1 Flood sensor functionality turned off 0
(Default)
Default flood sensor operation (flood detection, reactions)
  1 Built in flood sensor TURNED OFF (does not change its state in the main controller, does not send Alarms and Basic Set frames with flood state changes. Always visible in the main controller as turned off)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

78 1 Associations in Z-Wave network security mode 0 none of the groups sent as secure
  1 to 2 2nd group Flood Control sent as secure
  2 to 3 group Flood Alarm sent as secure
  4 group Tamper sent as secure

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Alarm cancelling or turning a device off (Basic) command frame deactivation 0 alarm (flooding) cancellation inactive
  1
(Default)
alarm (flooding) cancellation active