TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 2 | Alarm cancellation delay | 0 to 3600 (Default) |
in seconds, each 1s | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 4 | Temperature measurement interval | 1 to 65535 (Default) |
in seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Temperature measurement hysteresis | 1 to 1000 (Default) |
each 0.01 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Acoustic and visual signals On/Off in case of flooding | 0 | acoustic and visual alarms inactive | |
1 | acoustic alarm inactive, visual alarm active | ||||
2 | acoustic alarm active, visual alarm inactive | ||||
3 (Default) |
acoustic and visual alarms active | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
50 | 2 | Low temperature alarm threshold | -10000 to 10000 (Default) |
each 0.01 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
51 | 2 | High temperature alarm threshold | -10000 to 10000 (Default) |
each 0.01 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
61 | 4 | Low temperature alarm indicator colour | 0 to 16777215 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
62 | 4 | High temperature alarm indicator colour | 0 to 16777215 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
63 | 1 | Managing a visual indicator under standard operation | 0 | Visual indicator does not indicate the temperature | |
1 | Visual indicator indicates the temperature (blink) every Temperature Measurement Interval (Parameter 10, constant current and battery) or Wake Up Interval (battery mode) | ||||
2 (Default) |
Visual indicator indicates the temperature continuously, only in constant power mode | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 2 | Forced dimming level / roller blind opening level, when sending turn on / open command to 2nd association group devices | 1 to 99 | forced level | |
255 (Default) |
turn a device on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
73 | 2 | Temperature measurement compensation | -10000 to 10000 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
74 | 1 | Alarm frame sent to 1st and 4th Association Group activation (MOVEMENT_TAMPER / BUTTON_TAMPER) | 0 | tamper alarms inactive | |
1 | button tamper alarm active | ||||
2 (Default) |
button tamper alarm active | ||||
3 | button and movement tampers alarm active | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
75 | 4 | Visual and audible alarms duration | 0 (Default) |
alarms active indefinitely | |
1 to 65535 | time in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
76 | 4 | Alarm frame / Basic Set frame retransmission time when retaining flood alarm | 0 (Default) |
retransmission inactive | |
1 to 65535 | time in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
77 | 1 | Flood sensor functionality turned off | 0 (Default) |
Default flood sensor operation (flood detection, reactions) | |
1 | Built in flood sensor TURNED OFF (does not change its state in the main controller, does not send Alarms and Basic Set frames with flood state changes. Always visible in the main controller as turned off) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
78 | 1 | Associations in Z-Wave network security mode | 0 | none of the groups sent as secure | |
1 to 2 | 2nd group Flood Control sent as secure | ||||
2 to 3 | group Flood Alarm sent as secure | ||||
4 | group Tamper sent as secure | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Alarm cancelling or turning a device off (Basic) command frame deactivation | 0 | alarm (flooding) cancellation inactive | |
1 (Default) |
alarm (flooding) cancellation active | ||||