Z-Wave Products

There are over 4409 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: MultiSensor 6 (ZW100-C)

Z-Wave Certification Number: ZC10-15080001


Parameter Number

Parameter Size

Parameter Name

Parameter Values

102 4 To set which report would be sent in Report group 2 16 Ultraviolet Report is enabled.
  1 Battery Report is enabled.
  32 Temperature Report is enabled.
  128 Luminance Report is enabled.
  64 Humidity Report is enabled.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

111 4 To set the interval time of sending reports in Report group 1 -128 to 127 Available rang is -12.8℃ to 12.7℃.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

113 4 To set the interval time of sending reports in Report group 3 0 to 30000
(Default)
Available rang is 0 to 30000LUX.
  5 to 2678400
(Default)
Available rang is 5 to 2678400 seconds.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor. 0
(Default)
Disable
  1 Enable.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

201 2 Temperature sensor calibration 1 to 11 Available rang is 1 to 11.
  -128 to 127
(Default)
Available rang is -12.8℃ to 12.7℃.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

202 1 Humidity sensor calibration -50 to 50
(Default)
Available rang is -50RH to 50RH.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

203 2 Luminance sensor calibration -1000 to 1000
(Default)
Available rang is -1000Lux to 1000Lux.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

204 1 Ultraviolet sensor calibration -10 to 10
(Default)
Available rang is -10 to 10.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 4 Reset to factory defaults. 1 Reset all configuration parameters to factory defaults.
  1431655765 Reset the product to factory defaults.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 2 Set the PIR time. 10 to 3600
(Default)
The range of PIR time is 10 to 3600.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Set the sensitivity of the motion sensor. 1 Sensitivity Level 1 of 6
  5
(Default)
Maximum Sensitivity
  0 Minimum Sensitivity
  4 Sensitivity Level 5 of 6
  2 Sensitivity Level 2 of 6
  3 Sensitivity Level 3 of 6

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 Enable/disable the selective reporting only when measurements reach a certain threshold or percentage 257 Keep awake for 10 minutes for battery power mode.
  0
(Default)
Disable
  256 Keep sleep state for Battery power mode
  1 Enable.
  0
(Default)
USB power mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

43 2 Threshold change in luminance to induce an automatic report. 1 to 30000
(Default)
Available rang is 1 LUX to 30000 LUX.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

46 1 Enable/disable to send the alarm report of low temperature 1 to 100 Available rang is 1% to 100%.
  1 Enable.
  0
(Default)
Disable
  1 to 30000 Available rang is 1LUX to 30000LUX.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

48 1 Enable/disable to send a report when the measurement is more than the upper limit value or less than the lower limit value. 0
(Default)
Disable
  1 Enable.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

49 4 Set the upper limit value of temperature sensor. 0 Disable
  -400 to 2120
(Default)
Available rang is -40.0℉ to 212.0℉.
  1 Enable.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

52 1 Set the lower limit value of humidity sensor. 0 to 100
(Default)
Available rang is 0% to 100%.
  0 to 100
(Default)
Available rang is 0% to 100%.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

53 1 Set the upper limit value of Lighting sensor 0 to 100 Available rang is 0% to 100%.
  0 to 30000
(Default)
Available rang is 0 to 30000LUX.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

54 1 Set the lower limit value of Lighting sensor. 0 to 30000
(Default)
Available rang is 0 to 30000LUX.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

55 1 Set the upper limit value of ultraviolet sensor. 1 to 11
(Default)
Available rang is 1 to 11.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

56 1 Set the lower limit value of ultraviolet sensor. 1 to 11
(Default)
Available rang is 1 to 11.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

59 1 Set the recover limit value of Lighting sensor. 1 to 127
(Default)
Available rang is 10Lux to 1270Lux
  0 Disable
  1 to 127
(Default)
Available rang is 10Lux to 1270Lux
  1 Enable.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

60 1 Set the recover limit value of Ultraviolet sensor. 256 Keep sleep state for Battery power mode
  257 Keep awake for 10 minutes for battery power mode.
  0 USB power mode
  1 to 5
(Default)
Available rang is 1 to 5.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

61 2 Get the out-of-limit state of the Sensors. 8 Ultraviolet sensor is out of the lower limit
  32 Humidity sensor is out of the upper limit
  16 Temperature sensor is out of the upper limit
  2 Humidity sensor is out of the lower limit
  4 Luminance sensor is out of the lower limit
  64 Luminance sensor is out of the upper limit
  128 Ultraviolet sensor is out of the upper limit
  1 Temperature sensor is out of the lower limit

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 Set the timeout of awake after the Wake Up CC is sent out.. 8 to 127
(Default)
Available rang is 8 to 127 seconds.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 2 Report the current power mode and the product state for battery power mode 257 Keep awake for 10 minutes for battery power mode.
  256 Keep sleep state for Battery power mode
  0
(Default)
USB power mode