Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Which value of the Sensor Binary Report will be sent when the Sensor is triggered On or Off. | 0 (Default) |
When the Sensor is triggered On, Sensor Binary Report=0xFF. When the Sensor is triggered Off, Sensor Binary Report=0x00. | |
1 | When the Sensor is triggered On, Sensor Binary Report=0x00. When the Sensor is triggered Off, Sensor Binary Report=0xFF. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
111 | 4 | Set the interval time of battery report. | 0 (Default) |
The periodic battery report is disabled. | |
1 to 2147483647 | the range of interval time is 1 seconds to 2147483647 seconds. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
121 | 4 | To set which command will be sent to the associated nodes when the Sensor is triggered On/Off. | 16 | Send Sensor Binary Report to associated nodes when the Sensor is triggered On/Off. | |
256 (Default) |
Send Basic Set to associated nodes when the Sensor is triggered On/Off. | ||||
272 | Send the Sensor Binary Report and Basic Set to associated nodes when the Sensor is triggered On/Off. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
122 | 1 | Set a Notification type for Dry Contact Sensor. | 1 | The Smoke Alarm notification type is selected for the Sensor. | |
2 | The CO Alarm notification type is selected for the Sensor. | ||||
3 | The CO2 Alarm notification type is selected for the Sensor. | ||||
4 | The Heat Alarm notification type is selected for the Sensor. | ||||
5 | The Water Alarm notification type is selected for the Sensor. | ||||
6 (Default) |
The Access Control notification type is selected for the Sensor. | ||||
7 | The Home Security notification type is selected for the Sensor. | ||||
8 | The Power Management notification type is selected for the Sensor. | ||||
9 | The System notification type is selected for the Sensor. | ||||
10 | The Emergency Alarm notification type is selected for the Sensor. | ||||
11 | The Clock notification type is selected for the Sensor. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Enable/disable wake-up 10 minutes when re-power on the Sensor. | 0 | Disable. | |
1 (Default) |
Enable. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
255 | 4 | Reset the Sensor. | 0 (Default) |
Reset to factory default settings. | |
1431655765 | Reset to factory default settings and removed from the Z-Wave network. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Which value of the Basic Set will be sent when the Sensor is triggered On/Off. | 1 | When the Sensor is triggered On, Basic Set=0x00. When the Sensor is triggered Off, Basic Set=0xFF. | |
0 (Default) |
When the Sensor is triggered On, Basic Set=0xFF. When the Sensor is triggered Off, Basic Set=0x00. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
39 | 1 | Set the low battery value. | 10 to 50 (Default) |
The range of low battery value is 10% to 50% | |