Z-Wave Products

There are over 4376 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Dry Contact Sensor Gen5 (ZW097-A)

Z-Wave Certification Number: ZC10-15090010


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Which value of the Sensor Binary Report will be sent when the Sensor is triggered On or Off. 0
(Default)
When the Sensor is triggered On, Sensor Binary Report=0xFF. When the Sensor is triggered Off, Sensor Binary Report=0x00.
  1 When the Sensor is triggered On, Sensor Binary Report=0x00. When the Sensor is triggered Off, Sensor Binary Report=0xFF.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

111 4 Set the interval time of battery report. 0
(Default)
The periodic battery report is disabled.
  1 to 2147483647 the range of interval time is 1 seconds to 2147483647 seconds.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

121 4 To set which command will be sent to the associated nodes when the Sensor is triggered On/Off. 16 Send Sensor Binary Report to associated nodes when the Sensor is triggered On/Off.
  256
(Default)
Send Basic Set to associated nodes when the Sensor is triggered On/Off.
  272 Send the Sensor Binary Report and Basic Set to associated nodes when the Sensor is triggered On/Off.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

122 1 Set a Notification type for Dry Contact Sensor. 1 The Smoke Alarm notification type is selected for the Sensor.
  2 The CO Alarm notification type is selected for the Sensor.
  3 The CO2 Alarm notification type is selected for the Sensor.
  4 The Heat Alarm notification type is selected for the Sensor.
  5 The Water Alarm notification type is selected for the Sensor.
  6
(Default)
The Access Control notification type is selected for the Sensor.
  7 The Home Security notification type is selected for the Sensor.
  8 The Power Management notification type is selected for the Sensor.
  9 The System notification type is selected for the Sensor.
  10 The Emergency Alarm notification type is selected for the Sensor.
  11 The Clock notification type is selected for the Sensor.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Enable/disable wake-up 10 minutes when re-power on the Sensor. 0 Disable.
  1
(Default)
Enable.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 4 Reset the Sensor. 0
(Default)
Reset to factory default settings.
  1431655765 Reset to factory default settings and removed from the Z-Wave network.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Which value of the Basic Set will be sent when the Sensor is triggered On/Off. 1 When the Sensor is triggered On, Basic Set=0x00. When the Sensor is triggered Off, Basic Set=0xFF.
  0
(Default)
When the Sensor is triggered On, Basic Set=0xFF. When the Sensor is triggered Off, Basic Set=0x00.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

39 1 Set the low battery value. 10 to 50
(Default)
The range of low battery value is 10% to 50%