There are over 4290 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Garage Door Controller Gen5 (ZW062-C)

Z-Wave Certification Number: ZC10-15090012


Parameter Number

Parameter Size

Parameter Name

Parameter Values

241 4 Pair the Sensor with Garage Door Controller 1431655681 Start the Sensor pairing mode.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

252 1 Enable/Disable Lock Configuration 0
(Default)
All configuration parameters are configurable.
  1 All configuration parameters are not configurable (Locked).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 4 Reset to default factory setting 1 Reset all configuration parameters to default setting.
  1431655765 Reset the product to default factory setting and be excluded from the Z-wave network.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

32 1 Configure the default startup ringtone. 0 Disable the startup ringtone.
  1 to 100
(Default)
Enable and select a startup ringtone for the Garage Door Controller.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

34 1 Calibration the Sensor. 1 Enable calibration.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

35 2 Set the timeout of Sensor calibration. 1 to 32767
(Default)
Set the timeout of calibration

Parameter Number

Parameter Size

Parameter Name

Parameter Values

36 1 Get the number of alarm music. 1
(Default)
Get the number of alarm music.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

37 4 Configure the alarm mode when the garage door is opening. 1 to 10 Configure the flash frequency of the alarm LED, there are 10 levels can be set.
  16777215 Disable the alarm mode.
  65535 to 65545 Configure the volume of alarm sound, there are 10 levels can be set.
  256 to 356 Select an alarm sound, there are 4 alarm sounds in the flash memory card can be selected.
  16777216 Enable the alarm mode.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

38 4 Configure the alarm mode when the garage door is closing. 16777216 Enable the alarm mode.
  1 to 10 Configure the flash frequency of the alarm LED, there are 10 levels can be set.
  65535 to 65545 Configure the volume of alarm sound, there are 10 levels can be set.
  16777215 Disable the alarm mode.
  256 to 356 Select an alarm sound, there are 4 alarm sounds in the flash memory card can be selected.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

39 4 Configure the alarm mode when the garage door is in Unknown position. 1 to 10 Configure the flash frequency of the alarm LED, there are 10 levels can be set.
  65535 to 65545 Configure the volume of alarm sound, there are 10 levels can be set.
  16777215 Disable the alarm mode.
  16777216 Enable the alarm mode.
  256 to 356 Select an alarm sound, there are 4 alarm sounds in the flash memory card can be selected.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 4 Configure the alarm mode when the garage door is in closed position. 16777216 Enable the alarm mode.
  1 to 10 Configure the flash frequency of the alarm LED, there are 10 levels can be set.
  256 to 356 Select an alarm sound, there are 4 alarm sounds in the flash memory card can be selected.
  65535 to 65545 Configure the volume of alarm sound, there are 10 levels can be set.
  16777215 Disable the alarm mode.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

41 1 Configuration report for the tamper switch State 0
(Default)
The Sensor is installed on the garage door.
  15 The Sensor is removed from the garage door.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 1 Configuration report for the battery state of Sensor 15 Battery is in low battery state.
  0
(Default)
Battery is in normal state.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

43 1 Start playing or Stop playing the ringtone. -1 Stop playing the ringtone.
  1 to 100 Start playing the ringtone that you select.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

44 1 Test the volume of the current ringtone 1 to 10 There are 10 volume levels can be set for testing.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

45 2 Get the environment temperature 0 to 500
(Default)
The available temperature range is 0 to 50 Celsius

Parameter Number

Parameter Size

Parameter Name

Parameter Values

47 1 Define the function of Button- and Button+. 1 Pressing it once, the Button+ and Button- are defined to be the control item of Next and Previous. Press and hold it, the Button+ and Button- are defined to be used to increase and decrease the volume.
  0
(Default)
Pressing it once, the Button+ and Button- are defined to be used to increase and decrease the volume. Press and hold it, the Button+ and Button- are defined to be the control item of Next and Previous.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

80 1 Enable/Disable to send notifications to associated devices to associated devices. 2
(Default)
Send BARRIER OPERATOR Report Command
  0 Send Nothing (Disabled)
  1 Send HAIL Command