Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Smart Dimmer 6 (ZW099-C16)

Z-Wave Certification Number: ZC10-15100026


Parameter Number

Parameter Size

Parameter Name

Parameter Values

101 4 To set which report need to be sent. 2 Report Instantaneous Current (Amperes)
  4 Report Instantaneous Watts
  1 Report Instantaneous Voltage
  8 Report Accumulated kWh

Parameter Number

Parameter Size

Parameter Name

Parameter Values

102 4 To set which report need to be sent. 1 Report Instantaneous Voltage
  4 Report Instantaneous Watts
  8 Report Accumulated kWh
  2 Report Instantaneous Current (Amperes)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

103 4 To set which report need to be sent. 4 Report Instantaneous Watts
  8 Report Accumulated kWh
  1 Report Instantaneous Voltage
  2 Report Instantaneous Current (Amperes)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

111 4 Set the interval time of sending report. 0 to 268435456
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

112 4 Set the interval time of sending report. 0 to 268435456
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

113 4 Set the interval time of sending report. 0 to 268435456
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Configure the output load status after re-power on 2 The output load status will be OFF state after re-power on.
  1 The output load status will be ON state after re-power on.
  0
(Default)
The output load status will be the same as the previous state before a power outage.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

200 1 Partner ID 0
(Default)
Aeon Labs Standard Product
  1 to 255 Partner ID of Partner Product

Parameter Number

Parameter Size

Parameter Name

Parameter Values

252 1 Enable/Disable Lock Configuration 0
(Default)
All configuration parameters are configurable.
  1 All configuration parameters are not configurable (Locked).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

254 2 Device Tag 0 to 32767
(Default)
Device Tag

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 4 Reset to default factory setting 1431655765 Reset the product to default factory setting and be excluded from the Z-wave network.
  1 Reset all configuration parameters to default setting.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Current Overload Protection 0
(Default)
Overload Protection Disabled
  1 Overload Protection is Enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

33 4 Change the color value of RGB LED for testing 65536 to 16777215 Range of green color value.
  16777215 to 2147483647 Range of blue color value.
  0 to 255
(Default)
Reserved
  255 to 65535 Range of red color value.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

80 1 Enable/Disable to send notifications to associated devices to associated devices. 0
(Default)
Send Nothing (Disabled)
  1 Send HAIL Command
  2 Send BASIC Report Command

Parameter Number

Parameter Size

Parameter Name

Parameter Values

81 1 Configure the state of LED 1 The state of LED will follow with the output load state, but will turn off after 5 seconds if there is no any switch action.(Momentary indicate mode)
  2 The state of LED will the same with Night light mode state configured by parameter 83.
  0
(Default)
The state of LED will follow with the output load state(Energy mode)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

83 4 Configure the LED indication status when it is in Night light mode 65536 to 16777215
(Default)
Set the indication value of blue Led.
  0 to 255 Set the indication value of red Led.
  256 to 65535 Set the indication value of green Led.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

84 1 Configure the brightness level for the LED indication 0 to 100
(Default)
Brightness level range is 0 to 100%.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

90 1 Enable/Disable the function of parameter 91 and 92. 0 Configuration Parameters 91 and 92 are Disabled
  1
(Default)
Configuration Parameters 91 and 92 are Enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

91 2 Induce an automatic report 0 to 32767
(Default)
The threshold can be set from 0 to 32767 watt.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

92 1 Induce an automatic report 0 to 100
(Default)