There are over 4377 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
101 | 4 | Which report needs to be sent in Report group 1 | 64 | The humidity sensor report is selected. | |
128 | The light sensor report is selected. | ||||
1 | The battery report is selected. | ||||
32 | The temperature sensor report is selected. | ||||
16 | The ultraviolet sensor report is selected. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
102 | 4 | Which report needs to be sent in Report group 2. | 128 | The light sensor report is selected. | |
1 | The battery report is selected. | ||||
16 | The ultraviolet sensor report is selected. | ||||
32 | The temperature sensor report is selected. | ||||
64 | The humidity sensor report is selected. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
103 | 4 | Which report needs to be sent in Report group 3. | 64 | The humidity sensor report is selected. | |
128 | The light sensor report is selected. | ||||
1 | The battery report is selected. | ||||
16 | The ultraviolet sensor report is selected. | ||||
32 | The temperature sensor report is selected. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
111 | 4 | The interval time of sending reports in Report group 1 | 5 to 2678400 (Default) |
The range of interval time is 5 to 2678400. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
112 | 4 | The interval time of sending reports in Report group 2. | 5 to 2678400 (Default) |
The range of interval time is 5 to 2678400. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
113 | 4 | The interval time of sending reports in Report group 3 | 5 to 2678400 (Default) |
The range of interval time is 5 to 2678400. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor. | 1 | Enable waking up for 10 minutes when re-power on (battery mode) the MultiSensor. | |
0 (Default) |
Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
201 | 1 | Temperature calibration. | -32768 to 32767 (Default) |
The range of calibration value is -32768 to 32767. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
202 | 1 | Humidity sensor calibration. | -32768 to 32767 (Default) |
The range of calibration value is -32768 to 32767. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
203 | 2 | Luminance sensor calibration. | -32768 to 32767 (Default) |
The range of calibration value is -32768 to 32767. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
204 | 1 | Ultraviolet sensor calibration. | -11 to 11 (Default) |
The range of calibration value is -11 to 11. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
252 | 1 | Enable/disable all configuration parameters to be locked | 0 (Default) |
Disable all configuration parameters to be locked. | |
1 | Enable all configuration parameters to be locked. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
255 | 4 | Reset to default factory setting | 1 | Resets all configuration parameters to default setting. | |
1431655765 | Reset the product to default factory setting and be excluded from the Z-wave network. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 2 | Timeout of the motion sensor | 1 to 255 (Default) |
The unit of timeout is second. | |
256 to 15300 | The unit of timeout is minute. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
39 | 1 | Low battery value configuration. | 10 to 50 (Default) |
The range of low battery value is 10% to 50%. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Enable/disable the function of motion sensor. | 1 | Enable the function of motion sensor. | |
0 (Default) |
Disable the function of motion sensor. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 1 | Enable/disable the selective reporting only when measurements reach a certain threshold or percentage set in 41-44 below. | 1 | Enable the selective reporting. | |
0 (Default) |
Disable the selective reporting. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
41 | 2 | Threshold change in temperature to induce an automatic report. | 0 to 65535 (Default) |
Threshold of temperature. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
42 | 1 | Threshold change in humidity to induce an automatic report. | 0 to 100 (Default) |
Threshold of humidity | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
44 | 1 | Threshold change in battery level to induce an automatic report. | 0 to 1000 (Default) |
Threshold of luminance | |
0 to 100 (Default) |
Threshold of battery level. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
45 | 1 | Threshold change in ultraviolet to induce an automatic report. | 0 to 11 (Default) |
Threshold of ultraviolet. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
46 | 1 | Enable/disable to send the alarm report of low temperature | 0 (Default) |
Disable to send the alarm report of low temperature(<-15℃) | |
1 | Enable to send the alarm report of low temperature(<-15℃) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Which command would be sent when the motion sensor triggered. | 2 | Send Sensor Binary Report CC. | |
1 (Default) |
Send Basic Set CC. | ||||