There are over 4290 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Outputs status upon receipt of 1 click on its command | 1 (Default) |
TOGGLE | |
2 | ON | ||||
3 | OFF | ||||
4 | IGNORE | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | Timer to switch ON the Channel 1 | 0 (Default) |
Timer disabled | |
1 to 32000 | After this time the relay of the Channel 1 is ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | Timer to switch ON the Channel 2 | 0 (Default) |
Timer disabled | |
1 to 32000 | After this time the relay of the Channel 2 is ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Timer to switch OFF the Channel 1 | 0 (Default) |
Timer disabled | |
1 to 32000 | Timer disabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 2 | Timer to switch OFF the Channel 2 | 0 (Default) |
Timer disabled | |
1 to 32000 | After this time the relay of the Channel 2 is OFF | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Outputs status upon receipt of 2 clicks on its command | 1 (Default) |
TOGLE | |
2 | ON | ||||
3 | OFF | ||||
4 | IGNORE | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Outputs status upon receipt of a Multi-Channel Basic Set command | 1 (Default) |
AS RECEIVED | |
2 | IGNORE IF ON | ||||
3 | IGNORE IF OFF | ||||
4 | IGNORE | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Outputs status upon receipt of a Basic Set command | 1 | CHANNEL 1 | |
3 (Default) |
BOTH CHANNELS | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Type of outputs | 0 (Default) |
Channel 1 and Channel 2 are controlled individually | |
1 to 127 | The two channels are in opposite status. If the Channel 1 is close the Channel 2 is open, if the Channel 1 is open the Channel 2 is close. The value of the parameter defines the closing delay of the relay in tenth of seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Number of clicks that activate the control of the associated devices | 1 | Associated devices are controlled by 1 Click on the correspondent external switch | |
2 | Associated devices are controlled by 2 Clicks on the correspondent external switch | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Level used to control the devices associated to group 2 and 3 | 0 | The associated devices are switched OFF | |
-1 | The associated devices are switched ON | ||||
1 to 99 | The associated devices (dimmer, roller shutters) are set to the indicated level (only for devices associated to group 3) | ||||
100 (Default) |
If the Relay 1 is ON/OFF, the associated devices are ON/OFF | ||||
101 | If the Relay 1 is ON the associated devices are ON; if it is OFF no action is taken on the associated devices | ||||
102 | If the Relay 1 is OFF the associated devices are OFF; if it is ON no action is taken on the associated devices | ||||
103 | If the Relay 1 is ON the associated devices are OFF; if it is OFF no action is taken on the associated devices | ||||
104 | If the Relay 1 is OFF the associated devices are ON; if it is ON no action is taken on the associated devices | ||||
105 | If the Relay 1 is ON/OFF, the associated devices are OFF/ON | ||||
106 | No action is taken on the associated devices | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Level used to control the devices associated to group 4 and 5 | 0 | The associated devices are switched OFF | |
-1 | The associated devices are switched ON | ||||
1 to 99 | The associated devices (dimmer, roller shutters) are set to the indicated level (only for devices associated to group 5) | ||||
100 (Default) |
If the Relay 2 is ON/OFF, the associated devices are ON/OFF | ||||
101 | If the Relay 2 is ON the associated devices are ON; if it is OFF no action is taken on the associated devices | ||||
102 | If the Relay 2 is OFF the associated devices are OFF; if it is ON no action is taken on the associated devices | ||||
103 | If the Relay 2 is ON the associated devices are OFF; if it is OFF no action is taken on the associated devices | ||||
104 | If the Relay 2 is OFF the associated devices are ON; if it is ON no action is taken on the associated devices | ||||
105 | If the Relay 2 is ON/OFF, the associated devices are OFF/ON | ||||
106 | No action is taken on the associated devices | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
60 | 1 | Start-up status | 0 | Both Relay 1 and Relay 2 OFF | |
1 | Relay 1 ON, Relay 2 OFF | ||||
2 | Relay 1 OFF, Relay 2 ON | ||||
3 | Both Relay 1 and Relay 2 ON | ||||
4 (Default) |
Status prior to restart | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
61 | 1 | Configuration reset | 0 | The device is reset to the original factory settings | |
1 | All associations and only the associations are reset | ||||
2 | The associations are maintained while all other configuration parameters are reset to the original factory settings, except for the specific configuration. | ||||
3 | The device will be restarted | ||||
4 (Default) |
IGNORE | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
62 | 1 | Type of external switch | 0 | The actions on the external switch are ignored. In this mode, the device can only be controlled via the network. | |
1 | The external switch is a normally open button | ||||
2 | The external switch is a traditional switch | ||||
4 (Default) |
After the first single click on the external switch, the system automatically determines the type of external switch used and sets the parameter with the new value accordingly. | ||||