There are over 4393 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Which value of the Sensor Binary Report will be sent when the door is Opened/Closed. | 0 | Sensor Binary Report =0xFF when the door is Closed, Sensor Binary Report= 0x00 when the door is opened. | |
1 (Default) |
Sensor Binary Report= 0x00 when the door is closed, Sensor Binary Report=0xFF when the door is opened. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
111 | 4 | Set the interval time of battery report. | 0 to 2147483647 (Default) |
The range of interval can be set to 0 to 2147483647. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
121 | 4 | To configure which sensor report will be sent when the Sensor is triggered On/Off. | 16 | Basic Set CC is selected. | |
256 (Default) |
Sensor Binary Report CC is selected. | ||||
272 | Basic Set CC and Sensor Binary Report CC are selected. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Enable/disable wake up 10 minutes when re-power on the Sensor. | 0 | Disable. | |
1 (Default) |
Enable. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
255 | 4 | Reset the Sensor. | 0 (Default) |
Reset to default settings. | |
1431655765 | Reset to default settings and excluded from the network. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Which value of the Basic Set will be sent when the door is Opened/Closed. | 0 | Basic Set=0xFF when the door is Closed, Basic Set=0x00 when the door is opened. | |
1 (Default) |
Basic Set 0x00 when the door is Closed, Basic Set= 0xFF when the door is opened. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
39 | 1 | Set the low battery value. | 10 to 50 (Default) |
The range of low battery value can be set to 10% to 50%. | |