Z-Wave Products

There are over 4393 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Door/ Window Sensor Gen5 (ZW120-A)

Z-Wave Certification Number: ZC10-15110015


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Which value of the Sensor Binary Report will be sent when the door is Opened/Closed. 0 Sensor Binary Report =0xFF when the door is Closed, Sensor Binary Report= 0x00 when the door is opened.
  1
(Default)
Sensor Binary Report= 0x00 when the door is closed, Sensor Binary Report=0xFF when the door is opened.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

111 4 Set the interval time of battery report. 0 to 2147483647
(Default)
The range of interval can be set to 0 to 2147483647.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

121 4 To configure which sensor report will be sent when the Sensor is triggered On/Off. 16 Basic Set CC is selected.
  256
(Default)
Sensor Binary Report CC is selected.
  272 Basic Set CC and Sensor Binary Report CC are selected.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Enable/disable wake up 10 minutes when re-power on the Sensor. 0 Disable.
  1
(Default)
Enable.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 4 Reset the Sensor. 0
(Default)
Reset to default settings.
  1431655765 Reset to default settings and excluded from the network.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Which value of the Basic Set will be sent when the door is Opened/Closed. 0 Basic Set=0xFF when the door is Closed, Basic Set=0x00 when the door is opened.
  1
(Default)
Basic Set 0x00 when the door is Closed, Basic Set= 0xFF when the door is opened.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

39 1 Set the low battery value. 10 to 50
(Default)
The range of low battery value can be set to 10% to 50%.