Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Home Energy Meter Gen5 (ZW095-C)

Z-Wave Certification Number: ZC10-15120010


Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Percentage change in wattage to induce a automatic report 0 to 100
(Default)
The available range is 0 to 100.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

101 4 To set which report need to be sent. 1 Report Accumulated kWh of whole HEM
  2
(Default)
Report Instantaneous Watts of whole HEM.
  4 Report Instantaneous Voltage of whole HEM.
  8 Report Instantaneous Current (Amperes) of whole HEM.
  256 Report Instantaneous Watts of Channel 1.
  768 Report Instantaneous Watts of Channel 2.
  2048 Report Accumulated kWh of Channel 1.
  4096 Report Accumulated kWh of Channel 2.
  65535 Report Instantaneous Voltage of Channel 1.
  196608 Report Instantaneous Voltage of Channel 2.
  524288 Report Instantaneous Current (Amperes) of Channel 1.
  1048576 Report Instantaneous Current (Amperes) of Channel 2.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

102 4 To set which report need to be sent. 1
(Default)
Report Accumulated kWh of whole HEM
  2 Report Instantaneous Watts of whole HEM.
  4 Report Instantaneous Voltage of whole HEM.
  8 Report Instantaneous Current (Amperes) of whole HEM.
  256 Report Instantaneous Watts of Channel 1.
  768 Report Instantaneous Watts of Channel 2.
  2048 Report Accumulated kWh of Channel 1.
  4096 Report Accumulated kWh of Channel 2.
  65535 Report Instantaneous Voltage of Channel 1.
  196608 Report Instantaneous Voltage of Channel 2.
  524288 Report Instantaneous Current (Amperes) of Channel 1.
  1048576 Report Instantaneous Current (Amperes) of Channel 2.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

103 4 To set which report need to be sent. 1 Report Accumulated kWh of whole HEM
  2 Report Instantaneous Watts of whole HEM.
  4 Report Instantaneous Voltage of whole HEM.
  8 Report Instantaneous Current (Amperes) of whole HEM.
  256 Report Instantaneous Watts of Channel 1.
  768 Report Instantaneous Watts of Channel 2.
  2048 Report Accumulated kWh of Channel 1.
  4096 Report Accumulated kWh of Channel 2.
  65535 Report Instantaneous Voltage of Channel 1.
  196608 Report Instantaneous Voltage of Channel 2.
  524288 Report Instantaneous Current (Amperes) of Channel 1.
  1048576 Report Instantaneous Current (Amperes) of Channel 2.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

111 4 Set the interval time of sending report. 0 to 268435456
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

112 4 Set the interval time of sending report. 0 to 268435456
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

113 4 Set the interval time of sending report. 0 to 268435456
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Set the energy detection mode for parameter 101 to 103. 0
(Default)
Report absolute value for power and energy measurements.
  1 Report positive/negative power and report the algebraic sum energy
  2 Report positive/negative power and only report energy positive part (consuming electricity)
  3 Report positive/negative power and only report energy negative part (generating electricity).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

200 1 Partner ID 0
(Default)
Aeon Labs Standard Product
  1 to 127 Partner ID of Partner Product

Parameter Number

Parameter Size

Parameter Name

Parameter Values

252 1 Enable/Disable Lock Configuration 0
(Default)
All configuration parameters are configurable.
  1 All configuration parameters are not configurable (Locked)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 4 Reset to default factory setting 1 Resets all configuration parameters to default setting.
  1431655765 Reset the product to default factory setting and be excluded from the Z-wave network

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Enable/disable selective reporting only when power change reaches a certain threshold or percentage 0 Disable
  1
(Default)
Enable.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 2 Threshold change in wattage to induce a automatic report 0 to 60000
(Default)
The available range is 0 to 60000.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 2 Threshold change in wattage to induce a automatic report 0 to 60000
(Default)
The available range is 0 to 60000.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 2 Threshold change in wattage to induce a automatic report 0 to 60000
(Default)
The available range is 0 to 60000.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 Percentage change in wattage to induce a automatic report 0 to 100
(Default)
The available range is 0 to 100.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Percentage change in wattage to induce a automatic report 0 to 100
(Default)
The available range is 0 to 100.