There are over 4393 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Operation mode | 0 (Default) |
Door/Window Sensor or external alarm sensor | |
1 | external button | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | 2nd association group triggers | 0 (Default) |
switch after opening and closing | |
1 | switch after opening | ||||
2 | switch after closing | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | Commands sent to 2nd association group | 0 | ON | |
1 | OFF | ||||
2 (Default) |
ON & OFF | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Value of ON command frame sent to 2nd association group | 0 to 99 | turns OFF the device | |
255 (Default) |
turns it ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 2 | Value of OFF command frame sent to 2nd association group | 0 to 99 (Default) |
turns OFF the device | |
255 | turns it ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 2 | Time delay of ON command frame | 0 to 32400 (Default) |
time in seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 2 | Time delay of OFF command frame | 0 to 32400 (Default) |
time in seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Door/Window or alarm status | 0 (Default) |
door/window closed | |
1 | door/window opened | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Type of sent alarm frames | 0 (Default) |
Door/Window Sensor (General Purpose Alarm) | |
1 | smoke sensor (Smoke Alarm) | ||||
2 | CO detector (CO Alarm) | ||||
3 | CO2 detector (CO2 Alarm) | ||||
4 | high temperature sensor (Heat Alarm) | ||||
5 | flood sensor (Water Alarm) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Visual LED indications | 0 | no indications | |
1 | indication of opening/closing status change (input IN) | ||||
2 | indication of wake up (1 x click or periodical) | ||||
4 | indication of device tampering | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
30 | 2 | Delay of tamper alarm cancellation | 0 to 32400 (Default) |
time in seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
31 | 1 | Reporting tamper alarm cancellation | 0 | do not send tamper cancellation report | |
1 (Default) |
send tamper cancellation report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Range test after double click | 0 (Default) |
disabled | |
1 | enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
50 | 2 | Interval of temperature measurements | 0 | temperature measurements disabled | |
5 to 32400 (Default) |
time in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
51 | 2 | Temperature reports threshold | 0 | temperature reports based on threshold disabled | |
1 to 300 (Default) |
temperature threshold | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
52 | 2 | Interval of temperature reports | 0 (Default) |
periodic temperature reports disabled | |
5 to 32400 | time in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
53 | 4 | Temperature offset | -1000 to 1000 (Default) |
-100 – 100 degrees Celsius, in 0,1 degrees steps | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
54 | 1 | Temperature alarm reports | 0 (Default) |
temperature alarms disabled | |
1 | high temperature alarm | ||||
2 | low temperature alarm | ||||
3 | high and low temperature alarms enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
55 | 2 | High temperature alarm threshold | 0 to 1000 (Default) |
0 - 100 degrees Celsius, in 0,1 degrees steps | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
56 | 2 | Low temperature alarm threshold | -300 to 700 (Default) |
-30 - 70 degrees Celsius, in 0,1 degrees steps | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
70 | 2 | Scene activation functionality | 1 | [ID 10] opening door/window (single click) | |
2 | [ID 11] closing door/window (single click) | ||||
4 | [ID 12] holding | ||||
8 | [ID 13] releasing | ||||
16 | [ID 14] double click | ||||
32 | [ID 15] triple click | ||||
256 | [ID 50] high temperature - door/window opened | ||||
512 | [ID 50] high temperature - door/window closed | ||||
1024 | [ID 51] low temperature - door/window opened | ||||
2048 | [ID 51] low temperature - door/window closed | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
71 | 1 | Alarm broadcast | 0 (Default) |
broadcasts inactive | |
1 | ON/OFF commands broadcast active | ||||
2 | sensor alarm broadcast active | ||||
4 | tamper alarm broadcast active | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
72 | 1 | Associations in Z-Wave network Security Mode | 0 | none of the groups sent as secure | |
1 | 2nd group, Control, sent as secure | ||||
2 | 3rd group, Alarm, sent as secure | ||||
4 | 4th group, Sensor ZW3, sent as secure | ||||
8 | 5th group, Tamper ZW3, sent as secure | ||||