There are over 4290 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Vivint Element (CT200)

Z-Wave Certification Number: ZC10-16045048


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Temperature Reporting Threshold 0 to 4
(Default)
0 disabled 1 0.5F

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 4 Temperature Reporting Filter 0 "Byte 1 is the lower bound and can be 0 to 124 Byte 2 is the upper bound and can be 0 to 124 "

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Simple UI Mode Enable/Disable 0 to 1
(Default)
0=Normal 1=Simple

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Multicast Enable/Disable 0 to 1
(Default)
If set to 0, multicast is disabled, if set to 1, multicast is enabled.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Main Display Selection (CT110) 1 to 2
(Default)
1=Temperatue 2=RH

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 Save Energy Mode Type (CT110) 1 to 255
(Default)
"1 = Adjust target by delta (see 0x50, 58) 2 = Least consuming point in the running program 3 = Save energy absolute setpoint (Radio must adjust setpoint) 255 = Save Energy not supported by thermostat (read-only value) "

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 Fan Timer (CT200) 0 to 60
(Default)
0, 15 min, 30 min, 60 min

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 2 Humidity Control Activation (CT200) 0 "Byte 1 can be 0 or 1 Byte 2 can be 1 or 3"

Parameter Number

Parameter Size

Parameter Name

Parameter Values

17 1 Temperature Calibration (CT200) -6 to 6
(Default)
The valid values are from -6 to 6.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

18 1 Display Units (CT200) 0 to 1
(Default)
0=Fahrenheit 1=Celsius

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 4 HVAC Settings 0
(Default)
"Cooling Type (0, 1, 2, 3) Heating Type (0, 1, 2, 3) Heating Fuel (1, 2, 3, 4, 5) Number of Heat Stages (not Heat Pump) / Number of Aux Stages (Heat Pump) (1, 2)  A Terminal Assignment (0, 1, 2, 3, 4) Number of Heat Pump Stages (1, 2)  O/B Wire Selection (1,2)  Cooling Stages (1, 2)"

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Utility Lock Enable/Disable 0 to 255
(Default)
If set to 0, the utility lock is disabled, all other values will enable the utility lock.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 C-Wire / Battery Status 1 to 2 C-Wire (0x01) or Battery (0x02)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Humidity Reporting Threshold 0 to 3
(Default)
0=disabled 1=3%RH 2=5%RH 3=10%RH

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Auxiliary/Emergency 0 to 1
(Default)
0=disabled 1=enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Thermostat Swing Temperature 1 to 8
(Default)
The thermostat swing temperature is in units of 0.5 degrees Fahrenheit. A value of 0x01 is 0.5F and 0x02 is 1.0F. The supported values may vary from thermostat to thermostat but typically the allowed values are 0.5F (0x01) to 4.0F (0x08).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 2 Thermostat Diff Temperature 0 "The Thermostat Differential Mode determines which differential temperature to set. Valid values are 0x00 (Heat) or Cool (0x01) The thermostat differential temperature is in units of 0.5 degrees Fahrenheit. A value of 0x04 is 2.0F and 0x06 is 3.0F. The differential temperature must be an integer value. Non-integer values, such as 1.5F (0x03), should not be used. The supported values may vary from thermostat to thermostat but typically, the allowed values are 2.0F (0x04) to 6.0F (0x0C). "

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Thermostat Recovery Mode 1 to 2
(Default)
The Thermostat Recovery Mode can be either fast (0x01) or economy (0x02).