Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Temperature Reporting Threshold | 0 to 4 (Default) |
0 disabled 1 0.5F | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 4 | Temperature Reporting Filter | 0 | "Byte 1 is the lower bound and can be 0 to 124 Byte 2 is the upper bound and can be 0 to 124 " | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | Simple UI Mode Enable/Disable | 0 to 1 (Default) |
0=Normal 1=Simple | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Multicast Enable/Disable | 0 to 1 (Default) |
If set to 0, multicast is disabled, if set to 1, multicast is enabled. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Main Display Selection (CT110) | 1 to 2 (Default) |
1=Temperatue 2=RH | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | Save Energy Mode Type (CT110) | 1 to 255 (Default) |
"1 = Adjust target by delta (see 0x50, 58) 2 = Least consuming point in the running program 3 = Save energy absolute setpoint (Radio must adjust setpoint) 255 = Save Energy not supported by thermostat (read-only value) " | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | Fan Timer (CT200) | 0 to 60 (Default) |
0, 15 min, 30 min, 60 min | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 2 | Humidity Control Activation (CT200) | 0 | "Byte 1 can be 0 or 1 Byte 2 can be 1 or 3" | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 1 | Temperature Calibration (CT200) | -6 to 6 (Default) |
The valid values are from -6 to 6. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 1 | Display Units (CT200) | 0 to 1 (Default) |
0=Fahrenheit 1=Celsius | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 4 | HVAC Settings | 0 (Default) |
"Cooling Type (0, 1, 2, 3) Heating Type (0, 1, 2, 3) Heating Fuel (1, 2, 3, 4, 5) Number of Heat Stages (not Heat Pump) / Number of Aux Stages (Heat Pump) (1, 2)  A Terminal Assignment (0, 1, 2, 3, 4) Number of Heat Pump Stages (1, 2)  O/B Wire Selection (1,2)  Cooling Stages (1, 2)" | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Utility Lock Enable/Disable | 0 to 255 (Default) |
If set to 0, the utility lock is disabled, all other values will enable the utility lock. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | C-Wire / Battery Status | 1 to 2 | C-Wire (0x01) or Battery (0x02) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Humidity Reporting Threshold | 0 to 3 (Default) |
0=disabled 1=3%RH 2=5%RH 3=10%RH | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Auxiliary/Emergency | 0 to 1 (Default) |
0=disabled 1=enabled | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Thermostat Swing Temperature | 1 to 8 (Default) |
The thermostat swing temperature is in units of 0.5 degrees Fahrenheit. A value of 0x01 is 0.5F and 0x02 is 1.0F. The supported values may vary from thermostat to thermostat but typically the allowed values are 0.5F (0x01) to 4.0F (0x08). | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 2 | Thermostat Diff Temperature | 0 | "The Thermostat Differential Mode determines which differential temperature to set. Valid values are 0x00 (Heat) or Cool (0x01) The thermostat differential temperature is in units of 0.5 degrees Fahrenheit. A value of 0x04 is 2.0F and 0x06 is 3.0F. The differential temperature must be an integer value. Non-integer values, such as 1.5F (0x03), should not be used. The supported values may vary from thermostat to thermostat but typically, the allowed values are 2.0F (0x04) to 6.0F (0x0C). " | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Thermostat Recovery Mode | 1 to 2 (Default) |
The Thermostat Recovery Mode can be either fast (0x01) or economy (0x02). | |