TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Temperature Low Threshold | 246 to 69 | -10 to 69⁰C | |
0 | |||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Temperature High Threshold | 247 to 70 | -9 to 70⁰C | |
0 | |||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Meter Count | 0 to 2147483647 (Default) |
0 TO 2147483647 count rolls over at 99,999,999 | |
0 (Default) |
|||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Meter Reporting Interval | 0 to 255 (Default) |
0 to 2,550 seconds (0XFF) | |
0 | |||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Meter Threshold (low vs High flow) | 0 to 65535 (Default) |
0 to 65535 (0XFFFF) | |
0 | |||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | MultiLevel Sensor Report vs Notification Toggle | 0 to 255 (Default) |
0 = Notification, 1= MLS report | |
0 | |||||