There are over 4147 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Z-Wave Plus Micro Smart Plug ON/OFF (MSP-3-1-X1)

Z-Wave Certification Number: ZC10-16045035


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Default State 0 ON
  1 OFF
  2
(Default)
State before power outage

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 4 Alarm 3 Specifications 0 to 2097151999
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 Alarm 4 Type Configuration 0 to 65535
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 4 Alarm 4 Specifications 0 to 2097151999
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 2 Alarm 5 Type Configuration 0 to 65535
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 2 Alarm 6 Type Configuration 0 to 65535
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 4 Alarm 6 Specifications 0 to 2097151999
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

17 2 Alarm 7 Type Configuration 0 to 2097151999
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
  0 to 65535
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

18 4 Alarm 7 Specifications 0 to 2097151999
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

19 2 Alarm 8 Type Configuration 0 to 65535
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 4 Alarm 8 Specifications 0 to 2097151999
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Power Auto-Sending Report 0 Power Auto-Polling Report Disable
  1 to 100
(Default)
Power Auto-Polling Report Enable with 1% (to100%) differential

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 2 Overload Report 0 Overload Report Disable (Not Recommended)
  1 to 1840
(Default)
Overload Report enable with a upper limit of 1 W (to 1840 W)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 2 Energy Auto-Sending Report 0 Energy Auto-Polling Report Disable
  1 to 65535
(Default)
Energy Auto-Polling Report enable with 1 Wh (to 65535 Wh) diffential

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 2 Metering Pulse 0 Metering Pulse disable
  1 to 65535
(Default)
Metering Pulse enable and send report every 1 s (to 65535 s)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

25 2 Power High Threshold 0 Power High Threshold disable
  1 to 65535
(Default)
Power High Threshold enable with the value from 1 W (to 65535 W)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

26 2 Power Low Threshold 0 Power Low Threshold disable
  1 to 65535
(Default)
Power Low Threshold enable with the value from 1 W (to 65535 W)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

27 1 Power Threshold Action 0 Power Threshold Action is disable.
  1 Power High Threshold Action is enable and send the command OFF to Group 4
  3 Power High Threshold Action is enable and send the command ON to Group 4
  4 Power Low Threshold Action is enable and send the command OFF to Group 5
  12 Power Low Threshold Action is enable and send the command ON to Group 5

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Follow State 0 Group 2 and Group 3 disable
  1 Group 2 enable, Group 3 disable
  2 Group 2 disable, Group 3 enable
  3
(Default)
Group 2 and Group 3 enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Always ON 0
(Default)
Always ON disable
  1 Always ON enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 2 Alarm 1 Type Configuration 0 to 65535
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 4 Alarm 1 Specifications 0 to 2097151999
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 2 Alarm 2 Type Configuration 0 to 65535
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 4 Alarm 2 Specifications 0 to 2097151999
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 2 Alarm 3 Type Configuration 0 to 65535
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm