Z-Wave Products

There are over 4392 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: FIBARO Single Switch 2 (FGS-213)

Z-Wave Certification Number: ZC10-16075135


Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 First channel - operating mode 0
(Default)
standard operation
  1 delay ON function
  2 delay OFF function
  3 auto ON function
  4 auto OFF function
  5 flash function

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 First channel - reaction to switch for delay/auto ON/OFF modes 0
(Default)
cancel mode and set target state
  1 no reaction to switch - mode runs until it ends
  2 reset timer - start counting from the beginning

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 2 First channel - time parameter for delay/auto ON/OFF modes 0 0.1s
  1 to 32000
(Default)
1-32000s, 1s step

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 2 First channel - pulse time for flashing mode 1 to 32000
(Default)
(0.1-3200.0s, 0.1s step) - time parameter

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Switch type 0 momentary switch
  1 toggle switch (contact closed - ON, contact opened - OFF)
  2
(Default)
toggle switch (device changes status when switch changes status)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Flashing mode - reports 0
(Default)
the device does not send reports
  1 the device sends reports

Parameter Number

Parameter Size

Parameter Name

Parameter Values

27 1 Associations in Z-Wave network security mode 1 2nd group sent as secure
  2 3rd group sent as secure
  4 4th group sent as secure
  8 5th group sent as secure

Parameter Number

Parameter Size

Parameter Name

Parameter Values

28 1 S1 switch - scenes sent 1 Key pressed 1 time
  2 Key pressed 2 time
  4 Key pressed 3 time
  8 Key Hold Down and Key Released

Parameter Number

Parameter Size

Parameter Name

Parameter Values

29 1 S2 switch - scenes sent 1 Key pressed 1 time
  2 Key pressed 2 times
  4 Key pressed 3 times
  8 Key Hold Down and Key Released

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 1 S1 switch - associations sent to 2nd and 3rd association groups 1 ignore turning ON with 1 click of the switch
  2 ignore turning OFF with 1 click of the switch
  4 ignore holding and releasing the switch*
  8 ignore double click of the switch**

Parameter Number

Parameter Size

Parameter Name

Parameter Values

31 2 S1 switch - Switch ON value sent to 2nd and 3rd association groups 0 to 255
(Default)
sent value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

32 2 S1 switch - Switch OFF value sent to 2nd and 3rd association groups 0 to 255
(Default)
sent value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

33 2 S1 switch - Double Click value sent to 2nd and 3rd association groups 0 to 255
(Default)
sent value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

35 1 S2 switch - associations sent to 4th and 5th association groups 1 ignore turning on with 1 click of the switch
  2 ignore turning off with 1 click of the switch
  4 ignore holding and releasing the switch*
  8 ignore double click of the switch**

Parameter Number

Parameter Size

Parameter Name

Parameter Values

36 2 S2 switch - Switch ON value sent to 4th and 5th association groups 0 to 255
(Default)
sent value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

37 2 S2 switch - Switch OFF value sent to 4th and 5th association groups 0 to 255
(Default)
sent value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

38 2 S2 switch - Double Click value sent to 4th and 5th association groups 0 to 255
(Default)
sent value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 Reaction to General Alarm 0 alarm frame is ignored
  1 turn ON after receiving the alarm frame
  2 turn OFF after receiving the alarm frame
  3
(Default)
flash after receiving the alarm frame

Parameter Number

Parameter Size

Parameter Name

Parameter Values

41 1 Reaction to Flood Alarm 0 alarm frame is ignored
  1 turn ON after receiving the alarm frame
  2
(Default)
turn OFF after receiving the alarm frame
  3 flash after receiving the alarm frame

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 1 Reaction to CO/CO2/Smoke Alarm 0 alarm frame is ignored
  1 turn ON after receiving the alarm frame
  2 turn OFF after receiving the alarm frame
  3
(Default)
flash after receiving the alarm frame

Parameter Number

Parameter Size

Parameter Name

Parameter Values

43 1 Reaction to Heat Alarm 0 alarm frame is ignored
  1
(Default)
turn ON after receiving the alarm frame
  2 turn OFF after receiving the alarm frame
  3 flash after receiving the alarm frame

Parameter Number

Parameter Size

Parameter Name

Parameter Values

44 2 Flashing alarm duration 1 to 32000
(Default)
1-32000s, 1s step - duration

Parameter Number

Parameter Size

Parameter Name

Parameter Values

50 1 First channel - power reports 0 reports are disabled
  1 to 100
(Default)
change in power

Parameter Number

Parameter Size

Parameter Name

Parameter Values

51 1 First channel - minimal time between power reports 0 reports are disabled
  1 to 120
(Default)
1-120s - report interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

53 2 First channel - energy reports 0 reports are disabled
  1 to 32000
(Default)
1-32000 (1-32000Wh) - change in energy

Parameter Number

Parameter Size

Parameter Name

Parameter Values

58 2 Periodic power reports 0 periodic reports are disabled
  1 to 32000
(Default)
1-32000s - report interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

59 2 Periodic energy reports 0 periodic reports are disabled
  1 to 32000
(Default)
1-32000s - report interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

60 1 Measuring energy consumed by the device itself 0
(Default)
function inactive
  1 function active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Restore state after power failure 0 the device does not save the state prior to the power failure and returns to „off” position
  1
(Default)
the device restores its state prior to the power failure