There are over 4392 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: CT100 Plus (CT100)

Z-Wave Certification Number: ZC10-16085182


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Temperature Reporting Threshold 0 to 4
(Default)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Temperature Reporting Filter 0 to 31868
(Default)
Byte 1: 0 -124 (lower bound), Byte 2: 0-124 (upper bound)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Multicast 0 to 1
(Default)
0 = Disabled, 1 = Enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 Save Energy Mode Type 1 to 255
(Default)
1=Adjust by target delta, 2=Least consuming point in the running program, 3=Save energy absolute setpoint, 255=Save Energy not supported (read-only value)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 4 HVAC Settings 0 to 2147483647
(Default)
Byte 1: normal (1) or heat pump (2). Byte 2, Bits 7-4: Gas (1) or Electric (2). Byte 2, Bits 3-0: # of Auxiliary Stages. Byte 3: # of Heat Pump Stages. Byte 4: # of Cool Stages.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Utility Lock 0 to 255
(Default)
0 = Disabled, 1 - 255 = Enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 C-Wire/Battery 1 to 2 1=C-Wire, 2=Battery

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Humidity Reporting Threshold 0 to 3 0 = Disabled, 1 = 3% RH, 2 = 5% RH, 3 = 10% RH

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Auxiliary/Emergency Mode 0 to 1
(Default)
0 = Disabled, 1 = Enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Thermostat Swing Temperature 1 to 8
(Default)
1 = 0.5, 2 = 1.0, 3 = 1.5, 4 = 2.0, 5 = 2.5, 6 = 3.0, 7 = 3.5, 8 = 4.0

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 2 Thermostat Differential Temperature 2 to 6
(Default)
The thermostat differential temperature is in units of 0.5 degrees Fahrenheit.
  0 to 1 0x00 (Heat) or Cool (0x01)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Thermostat Recovery Mode 1 to 2
(Default)
1 = Fast, 2 = Economy