There are over 4392 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: MultiSensor 6 (ZW100-A)

Z-Wave Certification Number: ZC10-16065112


Parameter Number

Parameter Size

Parameter Name

Parameter Values

100 1 Set the parameter 101-103 to default values. 1 Set the parameter 101-103 to default values.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

101 4 To set which report would be sent in Report group 1 1 Battery Report is enabled.
  16 Ultraviolet Report is enabled.
  32 Temperature Report is enabled.
  64 Humidity Report is enabled.
  128 Luminance Report is enabled.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

102 4 To set which report would be sent in Report group 2 1 Battery Report is enabled.
  16 Ultraviolet Report is enabled.
  32 Temperature Report is enabled.
  64 Humidity Report is enabled.
  128 Luminance Report is enabled.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

103 4 To set which report would be sent in Report group 3 1 Battery Report is enabled.
  16 Ultraviolet Report is enabled.
  32 Temperature Report is enabled.
  64 Humidity Report is enabled.
  128 Luminance Report is enabled.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

111 4 To set the interval time of sending reports in Report group 1 5 to 2678400
(Default)
Available rang is 5 to 2678400 seconds.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

112 4 To set the interval time of sending reports in Report group 2 5 to 2678400
(Default)
Available rang is 5 to 2678400 seconds.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

113 4 To set the interval time of sending reports in Report group 3 5 to 2678400
(Default)
Available rang is 5 to 2678400 seconds.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor. 0
(Default)
Disable
  1 Enable.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

201 2 Temperature sensor calibration -128 to 127
(Default)
Available rang is -12.8℃ to 12.7℃.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

202 1 Humidity sensor calibration -50 to 50
(Default)
Available rang is -50RH to 50RH.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

203 2 Luminance sensor calibration -1000 to 1000
(Default)
Available rang is -1000Lux to 1000Lux.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

204 1 Ultraviolet sensor calibration -10 to 10
(Default)
Available rang is -10 to 10.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

252 1 Enable/disable all configuration parameters to be locked 0
(Default)
Disable
  1 Enable.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 4 Reset to factory defaults. 1 Reset all configuration parameters to factory defaults.
  1431655765 Reset the product to factory defaults.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 2 Set the PIR time. 10 to 3600
(Default)
The range of PIR time is 10 to 3600.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

39 1 Configure the default low battery value. 10 to 50
(Default)
Available rang is 10% to 50%.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Set the sensitivity of the motion sensor. 0 Minimum Sensitivity
  1 Sensitivity Level 1 of 6
  2 Sensitivity Level 2 of 6
  3 Sensitivity Level 3 of 6
  4 Sensitivity Level 5 of 6
  5
(Default)
Maximum Sensitivity

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 Enable/disable the selective reporting only when measurements reach a certain threshold or percentage 0
(Default)
Disable
  1 Enable.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

41 4 Threshold change in temperature to induce an automatic report. 10 to 2120
(Default)
Available rang of threshold is 1℉ to 212℉.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 1 Threshold change in humidity to induce an automatic report 1 to 100
(Default)
Available rang is 1% to 100%.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

43 2 Threshold change in luminance to induce an automatic report. 1 to 30000
(Default)
Available rang is 1 LUX to 30000 LUX.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

44 1 Threshold change in battery level to induce an automatic report. 1 to 100
(Default)
Available rang is 1% to 100%.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

45 1 Threshold change in ultraviolet to induce an automatic report. 1 to 11
(Default)
Available rang is 1 to 11.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

46 1 Enable/disable to send the alarm report of low temperature 1 to 30000 Available rang is 1LUX to 30000LUX.
  0
(Default)
Disable
  1 Enable.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

48 1 Enable/disable to send a report when the measurement is more than the upper limit value or less than the lower limit value. 0
(Default)
Disable
  1 Enable.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

49 4 Set the upper limit value of temperature sensor. -400 to 2120
(Default)
Available rang is -40.0℉ to 212.0℉.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Which command would be sent when the motion sensor triggered. 1
(Default)
Send Basic Set CC
  2 Send Sensor Binary Report CC

Parameter Number

Parameter Size

Parameter Name

Parameter Values

50 4 Set the lower limit value of temperature sensor. -400 to 2120
(Default)
Available rang is -40.0℉ to 212.0℉.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

51 1 Set the upper limit value of humidity sensor. 0 to 100
(Default)
Available rang is 0% to 100%.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

52 1 Set the lower limit value of humidity sensor. 0 to 100
(Default)
Available rang is 0% to 100%.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

53 1 Set the upper limit value of Lighting sensor 0 to 30000
(Default)
Available rang is 0 to 30000LUX.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

54 1 Set the lower limit value of Lighting sensor. 0 to 30000
(Default)
Available rang is 0 to 30000LUX.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

55 1 Set the upper limit value of ultraviolet sensor. 1 to 11
(Default)
Available rang is 1 to 11.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

56 1 Set the lower limit value of ultraviolet sensor. 1 to 11
(Default)
Available rang is 1 to 11.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

57 2 Set the recover limit value of temperature sensor. 10 to 255
(Default)
Available rang is 1.0℉ to 25.5℉

Parameter Number

Parameter Size

Parameter Name

Parameter Values

58 1 Set the recover limit value of humidity sensor. 1 to 50
(Default)
Available rang is 1 to 50%

Parameter Number

Parameter Size

Parameter Name

Parameter Values

59 1 Set the recover limit value of Lighting sensor. 1 to 127
(Default)
Available rang is 10Lux to 1270Lux

Parameter Number

Parameter Size

Parameter Name

Parameter Values

60 1 Set the recover limit value of Ultraviolet sensor. 0 USB power mode
  256 Keep sleep state for Battery power mode
  257 Keep awake for 10 minutes for battery power mode.
  1 to 5
(Default)
Available rang is 1 to 5.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

61 2 Get the out-of-limit state of the Sensors. 16 Temperature sensor is out of the upper limit
  32 Humidity sensor is out of the upper limit
  64 Luminance sensor is out of the upper limit
  128 Ultraviolet sensor is out of the upper limit
  1 Temperature sensor is out of the lower limit
  2 Humidity sensor is out of the lower limit
  4 Luminance sensor is out of the lower limit
  8 Ultraviolet sensor is out of the lower limit

Parameter Number

Parameter Size

Parameter Name

Parameter Values

64 1 Set the default unit of the automatic temperature report in parameter 101-103. 1 The unit is Celsius.
  2
(Default)
The unit is Fahrenheit.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 Set the timeout of awake after the Wake Up CC is sent out.. 8 to 127
(Default)
Available rang is 8 to 127 seconds.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

81 1 Enable/disable the LED blinking when the PIR is triggered. 0
(Default)
Enable.
  1 Disable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 2 Report the current power mode and the product state for battery power mode 256 Keep sleep state for Battery power mode
  257 Keep awake for 10 minutes for battery power mode.
  0
(Default)
USB power mode