Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
151 | 2 | Threshold of change in wattage | 0 | The function is disabled. | |
1 to 65535 (Default) |
The minimum change value in wattage for sending a meter report to the associated device | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
152 | 1 | Threshold of change in wattage percentage | 0 | The function is disabled. | |
1 to 255 (Default) |
The minimum change value in wattage percent for sending a meter report to the associated device | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
171 | 4 | Intervals of sending METER REPORT (for wattage) | 0 | The function is disabled | |
5 to 2678400 (Default) |
The time for sending a meter report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
172 | 4 | Intervals of sending METER REPORT (for kWh) | 0 | The function is disabled. | |
5 to 2678400 (Default) |
The time for sending a meter report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
173 | 4 | Intervals of sending METER REPORT (for voltage). | 0 (Default) |
The function is disabled | |
5 to 2678400 | The time for sending a meter report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
174 | 4 | Intervals of sending METER REPORT (for current). | 0 (Default) |
The function is disabled. | |
5 to 2678400 | The time for sending a meter report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Overcurrent protection | 0 | The function is disabled | |
1 (Default) |
The function is enabled. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Setting Smart Plug’s load status after re-power on | 0 (Default) |
Smart Plug memorizes its state after a power failure | |
1 | Connected device will be on after the power supply is reconnected | ||||
2 | Connected device will be off after the power supply is reconnected | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
24 | 1 | Notification when Load status change | 0 | The function is disabled | |
1 (Default) |
Send Basic report | ||||
2 | Send Basic report only when Load condition is not changed by Z-WAVE Command | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
27 | 1 | Indicator modes | 0 (Default) |
The Smart Plug will work in Power indication mode | |
1 | The Smart Plug will work in Power indication mode for 5 seconds, when the state of Smart Plug’s load changed. RGB LED indicator will turn off if there is no more switch action in 5 seconds. | ||||