There are over 3000 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z-Wave standard. Browse our Product Finder to see what Z-Wave can do for you.

Z-Wave Configuration Capabilities

Model: MIMO2+ (MIMO2+)

Z-Wave Certification Number: ZC10-16075155


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Relay 1 Configuration 0
(Default)
The relay will remain latched in the position it is commanded to (open/off or closed/on)
  -128 to 127
(Default)
Set this value to the amount of time in 100ms increments for the relay to remain closed/on before automatically returning to the open/off state. For example, a value of 2 = 0.2 Seconds.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 SIG 2 Lower Threshold, High -128 to 127
(Default)
Set this value to set the lower threshold high number

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 SIG 2 Lower Threshold, Low -128 to 127
(Default)
Set this to set the lower threshold low number.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 SIG 2 Upper Threshold, High -128 to 127
(Default)
Set this to set the upper threshold, high number

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 SIG 2 Upper Threshold, Low -128 to 127
(Default)
Set this to set the upper threshold low number

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Relay 2 Configuration 0 The relay will remain latched in the position it is commanded to (open/off or closed/on)
  -128 to 127
(Default)
Set this value to the amount of time in 100ms increments for the relay to remain closed/on before automatically returning to the open/off state. For example, a value of 2 = 0.2 Seconds.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 SIG 1 Multilevel Trigger Settings -128 to 127
(Default)
Set this value to trigger between thresholds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 SIG 1 Lower Threshold, High -128 to 127
(Default)
Set this value to set the lower threshold high number

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 SIG 1 Lower Threshold, Low -128 to 127
(Default)
Set this to set the lower threshold low number.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 SIG 1 Upper Threshold, High -128 to 127
(Default)
Set this to set the upper threshold, high number

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 SIG 1 Upper Threshold, Low -128 to 127
(Default)
Set this to set the upper threshold low number

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 SIG 2 Multilevel Trigger Settings -128 to 127
(Default)
Set this value to trigger between thresholds