There are over 4252 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
151 | 2 | Power Report Value Threshold | 1 to 65535 (Default) |
number of Watts the appliance needs to go over for the change to be reported | |
0 | disabled (it will not report power consumption based on value change) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
152 | 1 | Power Report Percentage Threshold | 1 to 255 (Default) |
percentage in power usage change the appliance needs to go over for the event to be reported | |
0 | disabled (it will not report power consumption based on percentage change) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
171 | 4 | Power Report Frequency | 5 to 2678400 (Default) |
number of seconds for the interval the Smart Plug will report power consumption | |
0 | disabled (it will not report power consumption) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
172 | 4 | Energy Report Frequency | 5 to 2678400 (Default) |
number of seconds for the interval the Smart Plug will report energy usage | |
0 | disabled (it will not report energy usage) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
173 | 4 | Voltage Report Frequency | 5 to 2678400 | number of seconds for the interval the Smart Plug will report voltage | |
0 (Default) |
disabled (default – it will not report voltage levels) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
174 | 4 | Electricity Report Frequency | 5 to 2678400 | number of seconds for the interval the Smart Plug will report energy current | |
0 (Default) |
disabled (default – it will not report electrical current levels) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Overload Protection | 0 | Disabled | |
1 (Default) |
Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | On/Off Status Recovery After Power Failure | 0 (Default) |
Smart Plug remembers the status prior to power outage and turns back to it (default) | |
1 | Smart Plug automatically turns ON once power is restored (it does not remember the status prior to power outage) | ||||
2 | Smart Plug automatically turns OFF once power is restored (it does not remember the status prior to power outage) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
24 | 1 | On/Off Status Change Notifications | 0 | disabled (it will not send status change notifications) | |
1 (Default) |
sends notification if status is changed manually or remotely via Z-Wave (default) | ||||
2 | sends notification ONLY if status is changed manually by pressing and releasing the Z-Wave button on the Smart Plug | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
27 | 1 | LED Indicator Control | 0 (Default) |
LED indicator will display power consumption whenever the device is plugged in (LED stays on at all times) | |
1 | LED indicator will display the level of power consumption for 5 seconds only whenever the device is turned on or off (LED indicator will stay off for most of the time) | ||||