There are over 4407 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Zooz Z-Wave Mini Plug (ZEN07)

Z-Wave Certification Number: ZC10-16085170


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Metering Report 0 Metering disabled
  1
(Default)
Metering enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Manual Control 0 manual control disabled
  1
(Default)
manual control enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 2 Metering Report Frequency 1 to 65536
(Default)
Number of seconds metering report is sent to controller

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Overload Protection 1 to 16
(Default)
Maximum number of Amperes to be accepted by the Mini Plug

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Overload Notification 1 to 13
(Default)
Maximum number of Amperes that will trigger overload LED notification on the Mini Plug

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 LED Notifications 0 LED disabled
  1
(Default)
LED enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Power Report Percentage Threshold 1 to 100
(Default)
Percentage of change in power consumption, voltage, electricity, or energy usage to be reported to controller by the Mini Plug

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 On/Off Status Recovery After Power Failure 0 Mini Plug automatically turns OFF once power is restored (it does not remember the status prior to power outage)
  1
(Default)
Mini Plug remembers the status prior to power outage and turns back to it

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 Auto Turn-Off Timer 0
(Default)
timer disabled
  1 timer enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 2 Auto Turn-Off Timer Settings 1 to 65535
(Default)
Number of minutes the Mini Plug will turn off after once the auto turn-off timer is enabled