Z-Wave Products

There are over 4252 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Qubino Flush Dimmer (ZMNHDD1)

Z-Wave Certification Number: ZC10-16115319


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Input 1 switch type 0
(Default)
Mono-stable switch type (push button) – button quick press turns between previous set Dimmer value and zero.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 2 Activate / deactivate functions ALL ON / ALL OFF 255
(Default)
ALL ON active, ALL OFF active.
  0 ALL ON is not active, ALL OFF is not active.
  1 ALL ON is not active, ALL OFF active.
  2 ALL ON active, ALL OFF is not active.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

100 1 Enable / Disable Endpoints I2 or select Notification Type and Event 0
(Default)
Endpoint, I2 disabled.
  1 Home Security; Motion Detection, unknown loc.
  2 CO; Carbon Monoxide detected, unknown loc.
  3 CO2; Carbon Dioxide detected, unknown loc.
  4 Water Alarm; Water Leak detected, unknown loc.
  5 Heat Alarm; Overheat detected, unknown loc.
  6 Smoke Alarm; Smoke detected, unknown loc.
  9 Sensor binary.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

101 1 Enable / Disable Endpoints I3 or select Notification Type and Event 0
(Default)
Endpoint, I3 disabled.
  1 Home Security; Motion Detection, unknown loc.
  2 CO; Carbon Monoxide detected, unknown loc..
  3 CO2; Carbon Dioxide detected, unknown loc.
  4 Water Alarm; Water Leak detected, unknown loc.
  5 Heat Alarm; Overheat detected, unknown loc.
  6 Smoke Alarm; Smoke detected, unknown loc.
  9 Sensor binary.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 Automatic turning off output after set time 0
(Default)
Auto OFF disabled.
  1 to 32536 1 second - 32536 seconds Auto OFF enabled with define time, step is 1 second.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

110 2 Temperature sensor offset settings 32536
(Default)
Offset is 0.0°C.
  1 to 100 value from 0.1°C to 10.0°C is added to actual measured temperature.
  1001 to 1100 value from -0.1°C to -10.0°C is subtracted to actual measured temperature.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 2 Automatic turning on output after set time 0
(Default)
Auto ON disabled.
  1 to 32535 1 second - 32535 seconds Auto ON enabled with define time, step is 1 second.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

120 1 Temperature sensor reporting 5
(Default)
0,5°C change.
  0 Reporting disabled.
  1 to 127
(Default)
0,1°C - 12,7°C, step is 0,1°C.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Input 2 switch type 0
(Default)
Mono-stable switch type (push button) – button quick press turns between previous set Dimmer value and zero.
  1 Bi-stable switch type.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Enable/Disable Additional Switch 0
(Default)
Single push button (connected to I1).
  1 Additional switch (connected to I1 and I2)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Enable/Disable Double click function 0
(Default)
Double click disabled.
  1 Double click enabled.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

250 1 Unsecure / Secure Inclusion 0
(Default)
Unsecure Inclusion.
  1 Secure Inclusion.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Input 2 contact type 0
(Default)
NO (normally open) input type.
  1 NC (normally close) input type.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 1 Saving the state of the device after a power failure 0
(Default)
Flush Dimmer module saves its state before power failure (it returns to the last position saved before a power failure).
  1 Flush Dimmer module does not save the state after a power failure, it returns to "off" position.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Input 3 contact type 0
(Default)
NO (normally open) input type.
  1 NC (normally close) input type.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 Power reporting in Watts on power change 0 Reporting disabled.
  1 to 100
(Default)
1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 2 Power reporting in Watts by time interval 0
(Default)
Reporting disabled.
  1 to 32767 1 second - 32767 seconds. Reporting enabled. Power report is send with time interval set by entered value.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

60 1 Minimum dimming value 1
(Default)
1% (minimum dimming value)
  1 to 98
(Default)
1% - 98%, step is 1%. Minimum dimming values is set by entered value.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

61 1 Maximum dimming value 99
(Default)
99% (Maximum dimming value).
  2 to 99
(Default)
2% - 99%, step is 1%. Maximum dimming values is set by entered value.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

65 2 Dimming time (soft on/off) 100
(Default)
1s
  50 to 255
(Default)
00 mseconds - 2550 mseconds (2,55s), step is 10 mseconds.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

66 2 Dimming time when key pressed 3
(Default)
3s
  1 to 255
(Default)
1 second – 255 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

67 1 Ignore start level 0
(Default)
Respect start level.
  1 Ignore start level.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

68 1 Dimming duration 0
(Default)
Dimming duration according to parameter 66.
  1 to 127 From 1 to 127 seconds.