There are over 4392 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Timeout Duration | 5 (Default) |
5 minutes | |
15 | 15 minutes | ||||
0 | Test(5S) | ||||
1 | 1 minute | ||||
30 | 30 minutes | ||||
255 | Disable timeout | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | Adjust timing of steps/levels | 4 to 255 | Steps/Levels | |
1 to 2 | Steps/Levels | ||||
3 (Default) |
Default | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | Adjust Steps/levels with “ALL ON/OFF” command | 1 (Default) |
Default | |
2 to 99 | Steps/Levels | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Adjust timing of stepsALL ON/OFF” command/levels with “ | 1 to 2 | Steps/Levels | |
3 (Default) |
Default | ||||
4 to 255 | Steps/Levels | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Motion sensing sensitivity | 1 | High Sensitivity | |
2 (Default) |
Medium Sensitivity (Default) | ||||
3 | Low Sensitivity | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | Enable/Disable Light Sensing | 0 (Default) |
Disabled (Default) | |
1 | Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 2 | Reset Cycle | 0 | Disable | |
1 | 10 seconds | ||||
2 (Default) |
20 seconds (Default) | ||||
3 | 30 seconds | ||||
4 | 45 seconds | ||||
5 to 109 | 15 second intervals, starting at 60 seconds | ||||
110 | 27 minutes 15 seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 1 | Switch Mode | 0 (Default) |
Disabled (Default) | |
1 | Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 1 | Switch Level | 0 (Default) |
Disabled (Default) | |
1 to 99 | Brightness Level | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 1 | Dim up rate | 0 (Default) |
Dim up the light to the default level quickly (Default) | |
1 | Dim up the light to the default level slowly | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
19 | 1 | Exclusion mode | 0 (Default) |
Press any button on the switch (Default) | |
1 | Press and release “ X” button, then press and release “ ON “ button | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Change brightness of associated light bulb(s) | 0 to 99 | Brightness levels | |
255 (Default) |
Default | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Operation Mode | 1 | Manual | |
2 | Vacancy | ||||
3 (Default) |
Occupancy | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Invert Switch | 0 (Default) |
Disabled | |
1 | Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Enable/Disable Motion Sensor | 0 | Disabled | |
1 (Default) |
Enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Adjust steps/levels with Remote | 1 (Default) |
Default | |
2 to 99 | Steps/Levels | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 2 | Adjust timing of steps/levels with Remote | 1 to 2 | Steps/Levels | |
3 (Default) |
Default | ||||
4 to 255 | Steps/Levels | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Adjust steps/levels | 2 to 99 | Steps/Levels | |
1 (Default) |
Default | ||||