There are over 4392 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: FIBARO KeyFob (FGKF-601)

Z-Wave Certification Number: ZC10-17035483


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 2 Lock Mode activation 9 to 28086 unlocking sequence
  0
(Default)
Lock Mode disabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Single button associations - operating mode 0
(Default)
single press switches state to opposite
  1 single press switches state to opposite, double press sets to maximum level
  2 single press turns on, double press turns off

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 Value sent to □ association group 1 to 99 orcing level of associated devices
  255
(Default)
setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 2 Value sent to ○ association group 1 to 99 forcing level of associated devices
  255
(Default)
setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 2 Value sent to x association group 1 to 99 forcing level of associated devices
  255
(Default)
setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 2 Value sent to Δ association group 1 to 99 forcing level of associated devices
  255
(Default)
setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 2 Value sent to - association group 255
(Default)
setting associated devices to the last remembered state or turning them on
  1 to 99 forcing level of associated devices

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 2 Value sent to + association group 1 to 99 forcing level of associated devices
  255
(Default)
setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

17 1 Paired buttons association for □ and ○ 0
(Default)
paired buttons association inactive
  1 paired buttons association active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

18 1 Paired buttons association for x and Δ 0
(Default)
paired buttons association inactive
  1 paired buttons association active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

19 1 Paired buttons association for - and + 0
(Default)
paired buttons association inactive
  1 paired buttons association active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 2 Lock Mode - time to lock and locking button 0 Lock Mode disabled
  5 to 1791
(Default)
calculated value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Scene activation for □ button 1 Key Pressed 1 time
  2 Key Pressed 2 times
  4 Key Pressed 3 times
  8 Key Held Down & Released

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 1 Scene activation for ○ button 1 Key Pressed 1 time
  2 Key Pressed 2 times
  4 Key Pressed 3 times
  8 Key Held Down & Released

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 1 Scene activation for x button 1 Key Pressed 1 time
  2 Key Pressed 2 times
  4 Key Pressed 3 times
  8 Key Held Down & Released

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 1 Scene activation for Δ button 1 Key Pressed 1 time
  2 Key Pressed 2 times
  4 Key Pressed 3 times
  8 Key Held Down & Released

Parameter Number

Parameter Size

Parameter Name

Parameter Values

25 1 Scene activation for - button 1 Key Pressed 1 time
  2 Key Pressed 2 times
  4 Key Pressed 3 times
  8 Key Held Down & Released

Parameter Number

Parameter Size

Parameter Name

Parameter Values

26 1 Scene activation for + button 1 Key Pressed 1 time
  2 Key Pressed 2 times
  4 Key Pressed 3 times
  8 Key Held Down & Released

Parameter Number

Parameter Size

Parameter Name

Parameter Values

29 2 Associations in Z-Wave network security mode 1 2nd group sent as secure
  2 rd group sent as secure
  4 4th group sent as secure
  8 5th group sent as secure
  16 6th group sent as secure
  32 7th group sent as secure
  64 8th group sent as secure
  128 9th group sent as secure
  256 10th group sent as secure
  512 11th group sent as secure
  1024 12th group sent as secure
  2048 13th group sent as secure

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 2 First scene sequence 0 to 1
(Default)
sequence disabled
  9 to 28086 value of sequence

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 2 Second scene sequence 0
(Default)
sequence disabled
  9 to 28086 value of sequence

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 2 Third scene sequence 0 to 3
(Default)
sequence disabled
  9 to 28086 value of sequence

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 2 Fourth scene sequence 0 to 4
(Default)
sequence disabled
  9 to 28086 value of sequence

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 2 Fifth scene sequence 9 to 28086 value of sequence
  0 to 5
(Default)
sequence disabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 2 Sixth scene sequence 9 to 28086 value of sequence
  0 to 6
(Default)
sequence disabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Sequences - timeout 5 to 30
(Default)
time to lock
  0