Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Battery Report Interval | 1 to 127 | Hours, unsigned | |
0 (Default) |
Disabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Group2 Temp Threshold | 1 to 50 (Default) |
Tenths of degrees, unsigned | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | Group2 Temp Interval | 0 (Default) |
Disabled | |
1 to 120 | Minutes, unsigned | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Basic Set ON Above RH | 1 to 100 | %, unsigned | |
0 (Default) |
Disabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Basic Set ON Below RH | 0 (Default) |
Disabled | |
1 to 100 | %, unsigned | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | Basic Set OFF Above RH | 0 (Default) |
Disabled | |
1 to 100 | %, unsigned | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | Basic Set OFF Below RH | 1 to 100 | %, unsigned | |
0 (Default) |
Disabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 1 | Group1 RH Threshold | 1 to 50 (Default) |
%, unsigned | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 1 | Group1 RH Interval | 0 (Default) |
Disabled | |
1 to 120 | Minutes, unsigned | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 1 | Group3 RH Threshold | 1 to 30 (Default) |
%, unsigned | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
19 | 1 | Group3 RH Interval | 1 to 120 | Minutes, unsigned | |
0 (Default) |
Disabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Basic Set ON Above Temp | 121 (Default) |
Disabled | |
-40 to 120 | Fahrenheit | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Basic Set Option | 2 | Enabled Registers 2, 5, 13, 14 | |
3 | Enable Registers 3, 4, 12, 15 | ||||
4 | Enabled Registers 3, 4, 13, 14 | ||||
1 (Default) |
Enable Registers 2, 5, 12, 15 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Temp Offset | -7 to 7 (Default) |
Degrees | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
22 | 1 | Humidity Offset | -7 to 7 (Default) |
% | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
23 | 1 | Humidity Filter Time Constant | 1 to 60 (Default) |
Minutes | |
0 | |||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Basic Set ON Below Temp | 121 (Default) |
Disabled | |
-40 to 120 | Fahrenheit | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Basic Set OFF Above Temp | 121 (Default) |
Disabled | |
-40 to 120 | Fahrenheit | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Basic Set OFF Below Temp | 121 (Default) |
Disabled | |
-40 to 120 | Fahrenheit | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Basic Set Attempts | 0 (Default) |
Disabled | |
1 to 5 | Number of extra attempts, unsigned | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Temp Units | 0 | Celsius | |
1 (Default) |
Fahrenheit | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Group1 Temp Threshold | 1 to 200 (Default) |
Tenths of degrees, unsigned | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Group1 Temp Interval | 1 to 120 | Minutes, unsigned | |
0 (Default) |
Disabled | ||||