Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Auto Report Battery Time | 0 to 127 (Default) |
0 means turn off auto report.The default value is 12.The tick time can setting by the configuration No.20. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Auto Report Temperature Time | 0 to 127 (Default) |
0 means turn off auto report.The default value is 12.The tick time can setting by the configuration No.20. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | Auto Report Humidity Time | 0 to 127 (Default) |
0 means turn off auto report.The default value is 12.The tick time can setting by the configuration No.20. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Auto Report Tick Interval | -128 to 127 (Default) |
The interval time for auto report each tick.Setting this configuration will effect configuration No.10, No.13 and No.14.Units of one minute. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Temperature Differential Report | 1 to 127 (Default) |
The temperature differential to report.0 means turn off this function.The unit is Fahrenheit. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
23 | 1 | Humidity Differential Report | 0 to 60 (Default) |
The humidity differential to report.0 means turn off this function. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Operation Mode | 41 | Setting the temperature scale.0:Fahrenheit,1:Celsius. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Customer Function | 16 | Notification Type,0:Using Notification Report.1:Using Sensor Binary Report. | |
32 | Disable Multi CC in auto report.(1:Disable,0:Enable) | ||||