There are over 4392 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Input 1 switch type | 1 | Bi-stable switch type | |
3 | 0-10V Temperature sensor (regulated output) | ||||
4 | 0-10V Illumination sensor (regulated output) | ||||
2 | Potentiometer (Flush Dimmer 0-10V is using set value the last received from potentiometer or from z-wave controller) | ||||
0 (Default) |
Default value - Mono- stable switch type (push button) – button quick press turns between previous set dimmer value and zero) | ||||
5 | 0-10V General purpose sensor (regulated output) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | Activate / deactivate functions ALL ON / ALL OFF | 2 | ALL ON active, ALL OFF is not active | |
255 (Default) |
Default value - ALL ON active, ALL OFF active | ||||
0 | ALL ON is not active, ALL OFF is not active | ||||
1 | ALL ON is not active, ALL OFF active | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | Automatic turning off output after set time | 0 (Default) |
Default value - Auto OFF disabled | |
1 to 32536 | = 1second - 32536 seconds Auto OFF enabled with define time, step is 1 second | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
110 | 2 | Temperature sensor offset settings | 32536 (Default) |
Default value - offset is 0.0 degrees celsius | |
1 to 100 | Value from 0.1 degrees celsius to 10.0 degrees celsius is added to actual measured temperature | ||||
1001 to 1100 | Value from -0.1 degrees celsius to -10.0 degrees celsius is subtracted to actual measured temperature | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Automatic turning on output after set time | 0 (Default) |
Default value - Auto ON disabled | |
1 to 32535 | = 1second - 32535 seconds Auto ON enabled with define time, step is 1 second | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
120 | 1 | Digital temperature sensor reporting | 5 (Default) |
Default value = 0,5 degrees celsius change | |
0 | Reporting disabled | ||||
1 to 127 (Default) |
0,1 degrees celsius - 12,7 degrees celsius, step is 0,1 degrees celsius | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
140 | 2 | Input I1 Sensor reporting | 5 (Default) |
Default value = 0,5 change | |
0 | Reporting disabled | ||||
1 to 10000 (Default) |
= 0,1 - 1000 step is 0,1 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
141 | 1 | Input I1 0-10V reporting threshold | 5 (Default) |
Default value = 5 (0,5V) | |
1 to 100 (Default) |
0,1 - 10V | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
143 | 2 | Minimum sensor range value | 0 (Default) |
Default value 0 = 0.0 degrees celsius / 0Lux / 0.0%rh | |
0 to 10000 (Default) |
Value from 0 to 1000 (resolution 0,1) | ||||
10001 to 20000 | Value from -0,1 to -1000 (resolution 0,1)alue from -0,1 to -1000 (resolution 0,1) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
144 | 2 | Maximum sensor range value | 10001 to 20000 | Value from -0,1 to -1000 (resolution 0,1) | |
1000 (Default) |
Default value - 1000 = 100.0 degrees celsius / 100Lux / 100%rh | ||||
0 to 10000 (Default) |
Value from 0 to 1000 (resolution 0,1) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Enable/Disable Double click function | 0 (Default) |
Default value - Double click disabled | |
1 | Double click enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
250 | 1 | Unsecure / Secure Inclusion | 0 (Default) |
Default value - Unsecure Inclusion | |
1 | Secure Inclusion | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
30 | 1 | Saving the state of the device after a power failure | 0 (Default) |
Default value - Flush Dimmer 0-10V module saves its state before power failure (it returns to the last position saved before a power failure) | |
1 | Flush Dimmer 0-10V module does not save the state after a power failure, it returns to "off" position | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
52 | 1 | Auto or manual selection | 0 (Default) |
Default value - Manual | |
1 | Auto | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
53 | 1 | PID value inside deadband | 0 (Default) |
Default value - PID value equal ZERO | |
1 | PID value set to LAST VALUE | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
54 | 1 | PID deadband | 1 (Default) |
Default value 1 (1%) | |
0 to 100 (Default) |
0 - 100%, step is 1% | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
55 | 1 | Integral sampling time | 5 (Default) |
Default value 5 (5s) | |
0 to 127 (Default) |
= 0s to 127s, step is 1s | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
56 | 2 | P parameter | 0 to 1000 (Default) |
P value, step is 1 | |
100 (Default) |
Default value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
57 | 2 | I parameter | 1 (Default) |
Default value | |
0 to 1000 (Default) |
I value, step is 1 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
58 | 2 | D parameter | 1 (Default) |
Default value | |
0 to 1000 (Default) |
D value, step is 1 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
60 | 1 | Minimum dimming value | 1 (Default) |
Default value = 1% (minimum dimming value) | |
1 to 98 (Default) |
= 1% - 98%, step is 1%. Minimum dimming values is set by entered value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
61 | 1 | Maximum dimming value | 2 to 99 (Default) |
= 2% - 99%, step is 1%. Maximum dimming values is set by entered value. | |
99 (Default) |
Default value = 99% (Maximum dimming value) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
65 | 2 | Dimming time (soft on/off) | 100 (Default) |
Default value 100 = 1s | |
50 to 255 (Default) |
= 500 mseconds - 2550 mseconds (2,55s), step is 10 mseconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
66 | 2 | Dimming time when key pressed | 3 (Default) |
Default value 3 = 3s | |
1 to 255 (Default) |
= 1 second - 255 seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
67 | 1 | Ignore start level | 0 (Default) |
Default value - Respect start level | |
1 | Ignore start level | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
68 | 1 | Dimming duration | 0 (Default) |
Default value - dimming duration according to parameter 66 | |
1 to 127 | From 1 to 127 seconds | ||||