TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
100 | 1 | Set 101-103 to default. | 1 | Set 101-103 to default value. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
101 | 4 | To set which report needs to be sent in Report group 1 | 1 | Send Meter Report for Voltage | |
2 | Send Meter Report for Current | ||||
4 | Send Meter Report for Watt | ||||
8 | Send Meter Report for kWh | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
102 | 4 | To set which report needs to be sent in Report group 2 | 1 | Send Meter Report for Voltage | |
2 | Send Meter Report for Current | ||||
4 | Send Meter Report for Watt | ||||
8 | Send Meter Report for kWh | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
103 | 4 | To set which report needs to be sent in Report group 3 | 1 | Send Meter Report for Voltage | |
2 | Send Meter Report for Current | ||||
4 | Send Meter Report for Watt | ||||
8 | Send Meter Report for kWh | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
110 | 1 | Set 111-113 to default. | 1 | Set 111-113 to default. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
111 | 4 | The time interval of sending Report group 1 | 1 to 2147483647 (Default) |
the available range is 1 to 2147483647 seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
112 | 4 | The time interval of sending Report group 2 | 1 to 2147483647 (Default) |
the available range is 1 to 2147483647 seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
113 | 4 | The time interval of sending Report group 3 | 1 to 2147483647 (Default) |
the available range is 1 to 2147483647 seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 2 | Make Dimmer blink | 1 to 255 | Specify the cycle of On/Off. | |
256 to 32512 (Default) |
Specify the time of Dimmer blinking. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Configure the output load status after re-power on | 0 (Default) |
Last status. | |
1 | Always On | ||||
2 | Always Off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
200 | 1 | Partner ID | 0 (Default) |
Aeon Labs Standard Product | |
1 to 255 | Others | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
252 | 1 | Enable/disable the Configuration parameters to be Locked. | 0 (Default) |
Disable | |
1 | Enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
254 | 2 | Device Tag | 1 to 32767 | The available range is 1 to 32767. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
255 | 4 | Reset the Smart Dimmer 6 | 0 (Default) |
Reset all configuration parameters to factory default setting | |
1431655765 | Reset Smart Dimmer 6 to factory default setting and exclude from the network | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Current overload protection | 0 (Default) |
Disable | |
1 | Enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
33 | 4 | Set the RGB LED color value for factory testing. | 1 to 255 | Blue color value | |
256 to 65280 | Green color value | ||||
65536 to 16711680 | Red color value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
80 | 1 | To set which notification report can be sent to associated Nodes in association Group 1 | 0 (Default) |
Send Nothing | |
1 | Send Hail CC | ||||
2 | Send Basic Report CC | ||||
3 | Send Hail CC when using Action Button to change the output load state. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
81 | 1 | Configure the state of LED | 0 (Default) |
Energy mode, the LED will follow the status (on/off) of its load | |
1 | Momentary indicate mode, when the state of Dimmer’s load changed, The LED will follow the status (on/off) of its load, but the LED will turn off after 5 seconds if there is no any switch action. | ||||
2 | Night light mode. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
83 | 4 | Configure the RGB value when it is in Night light mode. | 1 to 255 | Blue color value | |
256 to 65280 | Green color value | ||||
65536 to 16711680 (Default) |
Red color value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
84 | 4 | Configure the brightness level of RGB LED (0%-100%) when it is in Energy Mode/momentary indicate mode. | 0 to 99 | The brightness level of Green color | |
256 to 355 | The brightness level of Yellow color | ||||
65536 to 65635 | The brightness level of Red color | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
90 | 1 | Enable or disable the parameter 91 and 92 | 0 (Default) |
Disable | |
1 | Enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
91 | 2 | Minimum change in wattage (in terms of wattage) to induce a Meter Report | 0 to 60000 (Default) |
The available range is 0 to 60000 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
92 | 1 | Minimum change in wattage percent (in terms of percentage) to induce a Meter Report | 0 to 100 (Default) |
The available range is 0 to 100% | |