Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Input switch type | 0 (Default) |
Mono-stable switch type (push button) | |
1 | Bi-stable switch type | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | Activate / deactivate functions ALL ON / ALL OFF | 255 (Default) |
ALL ON active, ALL OFF active | |
0 | ALL ON is not active, ALL OFF is not active | ||||
1 | ALL ON is not active, ALL OFF active | ||||
2 | ALL ON active, ALL OFF is not active | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | Automatic turning off output after set time | 0 (Default) |
Auto OFF disabled | |
1 to 32536 | = 1second - 32536 seconds Auto OFF enabled with define time, step is 1 second | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
110 | 2 | Temperature sensor offset settings | 32536 (Default) |
Offset is 0.0 degrees Celsius | |
1 to 100 | Value from 0.1 degrees Celsius to 10.0 degrees Celsius is added to actual measured temperature | ||||
1001 to 1100 | Value from -0.1 degrees Celsius to 10.0 degrees Celsius to -10.0 degrees Celsius to 10.0 degrees Celsius is subtracted to actual measured temperature | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Automatic turning on output after set time | 0 (Default) |
Auto ON disabled | |
1 to 32535 | = 1second - 32535 seconds Auto ON enabled with define time, step is 1 second | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
120 | 1 | Digital temperature sensor reporting | 5 (Default) |
0,5 degrees Celsius change | |
0 | Reporting disabled | ||||
1 to 127 (Default) |
= 0,1 degrees Celsius - 12,7 degrees Celsius, step is 0,1 degrees Celsius | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Enable/Disable Double click function | 0 (Default) |
Double click disabled | |
1 | Double click enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
30 | 1 | Saving the state of the device after a power failure | 0 (Default) |
DIN Dimmer module saves its state before power failure (it returns to the last position saved before a power failure) | |
1 | DIN Dimmer module does not save the state after a power failure, it returns to "off" position | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 1 | Power reporting in Watts on power change | 0 | Reporting disabled | |
1 to 100 (Default) |
= 1% - 100% Reporting enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
42 | 2 | Power reporting in Watts by time interval | 0 (Default) |
Reporting disabled | |
1 to 32767 | = 1 second - 32767 seconds. Reporting enabled. Power report is send with time interval set by entered value. Please note, that too fast reporting can cause too much Z-Wave traffic resulting in Z-Wave poor response | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Working mode | 0 (Default) |
Dimmer mode | |
1 | Switch mode | ||||
0 (Default) |
|||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
60 | 1 | Minimum dimming value | 1 (Default) |
= 1% (minimum dimming value) | |
1 to 98 (Default) |
= 1% - 98%, step is 1%. Minimum dimming values is set by entered value. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
61 | 1 | Maximum dimming value | 99 (Default) |
= 99% (Maximum dimming value) | |
2 to 99 (Default) |
= 2% - 99%, step is 1%. Maximum dimming values is set by entered value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
65 | 2 | Dimming time (soft on/off) | 100 (Default) |
= 1s | |
50 to 255 (Default) |
= 500 mseconds - 2550 mseconds (2,55s), step is 10 mseconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
66 | 2 | Dimming time when key pressed | 3 (Default) |
= 3s | |
1 to 255 (Default) |
1 second - 255 seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
67 | 1 | Ignore start level | 0 (Default) |
Respect start level | |
1 | Ignore start level | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
68 | 1 | Dimming duration | 0 (Default) |
Dimming duration according to parameter 66 | |
1 to 127 | From 1 to 127 seconds | ||||