There are over 4401 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: In-Wall Dimmer (FT111-C)

Z-Wave Certification Number: ZC10-17035487


Parameter Number

Parameter Size

Parameter Name

Parameter Values

100 1 Set parameter 101-103 to default value. 0
(Default)
Reset the parameter 101-103

Parameter Number

Parameter Size

Parameter Name

Parameter Values

102 1 To set which reports need to be sent in Report group 2. 1 Send Meter Report of voltage (V)
  4 Send Meter Report of wattage (W)
  2 Send Meter Report of current (A)
  8 Send Meter Report of energy (kWh)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

103 1 To set which reports need to be sent in Report group 3. 2 Send Meter Report of current (A)
  4 Send Meter Report of wattage (W)
  8 Send Meter Report of energy (kWh)
  1 Send Meter Report of voltage (V)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

110 1 Set parameter 111-113 to default value. 0
(Default)
Reset the parameter 111-113

Parameter Number

Parameter Size

Parameter Name

Parameter Values

111 4 Set the interval of automatic report for Report group 1. 1 to 2147483647
(Default)
The range of interval time is 1 to 2147483647.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

112 4 Set the interval of automatic report for Report group 2. 1 to 2147483647
(Default)
The range of interval time is 1 to 2147483647.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

113 4 Set the interval of automatic report for Report group 2. 1 to 2147483647
(Default)
The range of interval time is 1 to 2147483647.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

120 1 Configure the external switch mode for S1. 0
(Default)
Enter automatic identification mode
  1 Momentary push button mode
  2 3 way switch mode
  3 2-state switch mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

121 1 Configure the external switch mode for S2. 1 Momentary push button mode
  2 3 way switch mode
  3 2-state switch mode
  0
(Default)
Enter automatic identification mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

122 1 Get the state of touch panel port 0
(Default)
the touch panel is not connected.
  5 the touch panel is connected.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

123 1 Set the control destination for external switch S1 1 control the output loads of itself.
  3
(Default)
control the output loads of itself and other nodes.
  2 control the other nodes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

124 1 Set the control destination for external switch S2 1 control the output loads of itself.
  2 control the other nodes.
  3
(Default)
control the output loads of itself and other nodes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

125 1 Set the default dimming rate. 1 to 255
(Default)
The value range is 1 to 255 seconds.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

128 1 Get the current working mode 0
(Default)
Unknown working mode.
  1 2-wire mode
  2 3-wire mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

129 1 Set the dimming principle 0 Trailing edge mode
  1
(Default)
Leading edge mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

130 1 To get what type of load the Dimmer is connected to. 1 Resistive load
  2 Capacitive load
  3 Inductive load
  0
(Default)
Unknown load.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

131 1 Set the min brightness level that the load can reach to. 0 to 99
(Default)
The level range is 0 to 99.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

132 1 Set the max brightness level that the load can reach to. Note: 0 to 99
(Default)
The level range is 0 to 99.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Configure the output status after re-power on it. 1 Always on
  0
(Default)
Last status
  2 Always off

Parameter Number

Parameter Size

Parameter Name

Parameter Values

249 1 Set the recognition way of load 0 Never recognize the load when power on
  1 Only recognize once when first power on
  2
(Default)
Recognize the load once power on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

252 1 Lock/unlock configuration parameters 0
(Default)
Unlock
  1 Lock

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 4 Reset the In-Wall Dimmer 0
(Default)
Reset all configuration parameters to factory default setting
  1431655765 Reset to factory default setting and removed from the z-wave network

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Current Overload Protection. 1
(Default)
Enable
  0 Disable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Overheat protection. 0
(Default)
Disable
  1 Enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

80 1 To set which notification would be sent to the associated devices (Group 1) 0
(Default)
Send Nothing
  1 Send Hail CC
  2 Send Basic CC report
  3 Send Multilevel Switch report
  4 Send Hail CC when using the manual switch to change the load state.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

81 1 To set which notification would be sent to the associated nodes in association group 3 1
(Default)
Send Basic Set CC
  0 Send Nothing

Parameter Number

Parameter Size

Parameter Name

Parameter Values

82 1 To set which notification would be sent to the associated nodes in association group 4 0 Send Nothing
  1
(Default)
Send Basic Set CC

Parameter Number

Parameter Size

Parameter Name

Parameter Values

85 4 Set appointment 1 16777215 to 16777222 The day value (Mon to Sun)
  256 to 316 The minute value of ON time
  65536 to 65560 The hour value of ON time
  0 to 99 The brightness level

Parameter Number

Parameter Size

Parameter Name

Parameter Values

86 4 Set appointment 2 16777215 to 16777222 The day value (Mon to Sun)
  0 to 99 The brightness level
  256 to 316 The minute value of ON time
  65536 to 65560 The hour value of ON time

Parameter Number

Parameter Size

Parameter Name

Parameter Values

90 1 Enables/disables parameter 91 and 92 below: 0
(Default)
Disable
  1 Enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

91 2 Set the threshold value of wattage. 0 to 60000
(Default)
The thershold value range is 0 to 60000

Parameter Number

Parameter Size

Parameter Name

Parameter Values

92 1 Set the threshold value of wattage. 0 to 100
(Default)
The thershold value range is 0 to 100