Z-Wave Products

There are over 4102 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Garage Door Controller Gen5 (ZW062-A)

Z-Wave Certification Number: ZC10-17085731


Parameter Number

Parameter Size

Parameter Name

Parameter Values

241 4 Pair the Sensor with Garage Door Controller 1431655681 trigger to start the pairing of Sensor

Parameter Number

Parameter Size

Parameter Name

Parameter Values

252 1 Enable/disable to lock the configuration parameters. 0
(Default)
Disable
  1 Enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 4 Reset rhe Garage Door Controller 1 Reset all configuration parameters to factory default settings
  1431655765 Reset the device to factory default and excluded from the network

Parameter Number

Parameter Size

Parameter Name

Parameter Values

32 1 Configure the default startup ringtone. 0 disable the startup ringtone.
  1 to 127
(Default)
enable and select a startup ringtone for the Garage Door Controller.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

34 1 Sensor Calibration. 1 Garage Door Controller enters calibration mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

35 1 Set the timeout of all calibration steps for the Sensor. 1 to 127
(Default)
The time unit is second and time range is 1 to 127 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

36 1 Get the numbers of alarm music. 1 Get the numbers of alarm music

Parameter Number

Parameter Size

Parameter Name

Parameter Values

37 4 Configure the alarm mode when the garage door is opening. 0 disable the alarm prompt.
  1 enable the alarm prompt.
  256 to 266 configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the max volume is 10 levels
  65536 to 65636 configure the alarm sound
  16777216 to 16777226 configure the frequency of blinking for the Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is level 1 and the max frequency is level 10.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

38 4 Configure the alarm mode when the garage door is closing 0 disable the alarm prompt.
  1 enable the alarm prompt.
  256 to 266 configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the max volume is 10 levels
  65536 to 65636 configure the alarm sound
  16777216 to 16777226 configure the frequency of blinking for the Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is level 1 and the max frequency is level 10.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

39 4 Configuration alarm mode when the garage door is in "unknown" position 0 disable the alarm prompt.
  1 enable the alarm prompt.
  256 to 266 configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the max volume is 10 levels
  65536 to 65636 configure the alarm sound
  16777216 to 16777226 configure the frequency of blinking for the Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is level 1 and the max frequency is level 10.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 Configure the alarm mode when the garage door is in closed position 0 disable the alarm prompt.
  1 enable the alarm prompt.
  256 to 266 configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the max volume is 10 levels
  65536 to 65636 configure the alarm sound
  16777216 to 16777226 configure the frequency of blinking for the Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is level 1 and the max frequency is level 10.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

41 1 Configuration Report for the tamper switch state 0
(Default)
Sensor is not removed
  15 Sensor is removed

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 1 Configuration report for the battery state of Sensor 0
(Default)
battery power is much more.
  15 battery power of Sensor is in low battery.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

43 1 Start playing or Stop playing the ringtone -1 stop playing ringtone
  1 to 100 start playing the ringtone that you selected.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

44 1 Test the volume of the current ringtone 1 to 10 the volume level 1 to level 10.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

45 2 Get the environment temperature 0 to 500
(Default)
Rang is 0 to 500 (0℃ to 50.0℃).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

47 1 Define the function of Button- or Button+ 0
(Default)
short pressing the “Button +/-” will be used to adjust the volume of sound. Long pressing the “Button +/-” will be used to switch the sound to the next.
  1 short pressing the “Button +/-” will be used to switch the sound to the next. Long pressing the “Button +/-” will be used to adjust the volume of sound

Parameter Number

Parameter Size

Parameter Name

Parameter Values

80 1 It will send the Hail CC/configuration report CC when the state of garage door is changed 1 send Hail CC
  2
(Default)
send Barrier operator report CC