There are over 4408 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Nano Switch (ZW116-C)

Z-Wave Certification Number: ZC10-17035496


Parameter Number

Parameter Size

Parameter Name

Parameter Values

100 1 Set parameter 101-103 to default value. 0
(Default)
Reset the parameter 101-103

Parameter Number

Parameter Size

Parameter Name

Parameter Values

101 4 To set which reports need to be sent in Report group 1. 4 Send Meter Report of voltage (V)
  2 Send Meter Report of wattage (W)
  8 Send Meter Report of current (A)
  1 Send Meter Report of energy (kWh)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

102 4 To set which reports need to be sent in Report group 2. 1 Send Meter Report of energy (kWh)
  2 Send Meter Report of wattage (W)
  4 Send Meter Report of voltage (V)
  8 Send Meter Report of current (A)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

103 4 To set which reports need to be sent in Report group 3. 1 Send Meter Report of voltage (V)
  2 Send Meter Report of current (A)
  4 Send Meter Report of wattage (W)
  8 Send Meter Report of energy (kWh)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

110 1 Set parameter 111-113 to default value. 0
(Default)
Reset the parameter 111-113

Parameter Number

Parameter Size

Parameter Name

Parameter Values

111 4 Set the interval of automatic report for Report group 1. 1 to 2147483647
(Default)
The range of interval time is 1 to 2147483647.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

112 4 Set the interval of automatic report for Report group 2. 1 to 2147483647
(Default)
The range of interval time is 1 to 2147483647.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

113 4 Set the interval of automatic report for Report group 2. 1 to 2147483647
(Default)
The range of interval time is 1 to 2147483647.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

120 1 Configure the external switch mode for S1. 0
(Default)
Enter automatic identification mode
  1 2-state switch mode
  2 3 way switch mode
  3 Momentary push button mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

121 1 Configure the external switch mode for S2. 0
(Default)
Enter automatic identification mode
  1 2-state switch mode
  2 3 way switch mode
  3 Momentary push button mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

122 1 Set the control destination for external switch 1 control the output loads of itself.
  2 control the other nodes
  3
(Default)
control the output loads of itself and other nodes.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Configure the output status after re-power on it. 1 Always on
  0
(Default)
Last status
  2 Always off

Parameter Number

Parameter Size

Parameter Name

Parameter Values

252 1 Lock/unlock configuration parameters 0
(Default)
Unlock
  1 Lock

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 4 Reset the Nano Switch 0
(Default)
Reset all configuration parameters to factory default setting
  1431655765 Reset to factory default setting and removed from the z-wave network

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Current Overload Protection. 1
(Default)
Enable
  0 Disable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Overheat protection. 0
(Default)
Disable
  1 Enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

80 1 To set which notification would be sent to the associated devices (Group 1) 0 Send Nothing
  1 Send Hail CC
  3
(Default)
Send Hail CC when using the manual switch to change the load state.
  2 Send Basic Report CC

Parameter Number

Parameter Size

Parameter Name

Parameter Values

81 1 To set which notification would be sent to the associated nodes in association group 3 0 Send Nothing
  1
(Default)
Send Basic Set CC

Parameter Number

Parameter Size

Parameter Name

Parameter Values

82 1 To set which notification would be sent to the associated nodes in association group 4 0 Send Nothing
  1
(Default)
Send Basic Set CC

Parameter Number

Parameter Size

Parameter Name

Parameter Values

83 1 Configure the state of LED when it is in 3 modes 2 Night light mode. The LED will remain ON state.
  0
(Default)
Energy mode. The LED will follow the status (on/off).
  1 Momentary indicate mode. When the state of Switch’s load changed, the LED will follow the status (on/off) of its load, but the LED will turn off after 5 seconds if there is no any switch action.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

84 4 Set the ON/OFF time of the LED when it is in Night light mode. 0 to 60 The minute time of OFF
  256 to 316 The hour time of OFF
  65536 to 65596 The minute time of ON
  16777216 to 16777276 The hour time of ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

86 4 Set appointment 1 65536 to 65543 The day value (Mon to Sun)
  16777216 Enable the setting.
  256 to 316 The hour value of ON time
  16777215 Disable the setting.
  0 to 60 The minute value of ON time

Parameter Number

Parameter Size

Parameter Name

Parameter Values

87 4 Set appointment 2 256 to 316 The hour value of ON time
  65536 to 65543 The day value (Mon to Sun)
  16777215 Disable the setting.
  0 to 60 The minute value of ON time
  16777216 Enable the setting.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

90 1 Enables/disables parameter 91 and 92 below: 0
(Default)
Disable
  1 Enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

91 2 Set the threshold value of wattage. 0 to 60000
(Default)
The thershold value range is 0 to 60000

Parameter Number

Parameter Size

Parameter Name

Parameter Values

92 1 Set the threshold value of wattage. 0 to 100
(Default)
The thershold value range is 0 to 100