Z-Wave Products

There are over 4377 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: FIBARO Door/Window Sensor 2 (FGDW-002)

Z-Wave Certification Number: ZC10-17045530


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Door window state This parameter allows to set in what state is door window when the magnet is close to the sensor. 0 - closed when magnet near 1 - opened when magnet near

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No Yes

From

 

To

Description

0   0 closed when magnet near
1   1 opened when magnet near

Parameter Number

Parameter Size

Parameter Name

Description

11 1 2nd association group triggers Parameter defines events which result in sending on-off commands to devices added to the 2nd association group. These commands are sent alternately to switch the devices on and off. 0 - switch after opening and closing 1 - switch after opening (parameter 12) 2 - switch after closing (parameter 13)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No Yes

From

 

To

Description

1   1 switch after opening (parameter 12)
2   2 switch after closing (parameter 13)
0   0 switch after opening and closing

Parameter Number

Parameter Size

Parameter Name

Description

12 2 Association for opening - value sent Value sent to devices in 2nd association group when opening is detected. The value of 0 turns OFF the device, 255 turns it On. In case of associating devices allowing smooth control, values 1-99 allow to set an associated device to a specified level.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

255 0 255 No No Yes

From

 

To

Description

0   0 turns OFF the device
255   255 turns ON the device

Parameter Number

Parameter Size

Parameter Name

Description

13 2 Association for closing - value sent Value sent to devices in 2nd association group when closing is detected The value of 0 turns OFF the device, 255 turns it On. In case of associating devices allowing smooth control, values 1-99 allow to set an associated device to a specified level.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 255 No No Yes

From

 

To

Description

0   0 turns OFF the device
255   255 turns ON the device

Parameter Number

Parameter Size

Parameter Name

Description

14 2 Association for opening - time delay Time that must elapse from opening to send the command frame to to devices in 2nd association group. 0-32400 - time in seconds

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 32400 No No Yes

From

 

To

Description

0   32400 time in seconds

Parameter Number

Parameter Size

Parameter Name

Description

15 2 Association for closing - time delay Time that must elapse from closing to send the command frame to devices in 2nd association group. 0-32400- time in seconds

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 32400 No No Yes

From

 

To

Description

0   32400 time in seconds

Parameter Number

Parameter Size

Parameter Name

Description

2 1 Visual LED indications This parameter defines events indicated by the visual LED indicator. Disabling events might extend battery life. 1 - indication of opening-closing status change 2 - indication of wake up (1 x click or periodical) 4 - indication of device tampering NOTE Parameter 2 values may be combined, e.g. 1+2=3 means that in -dications for opening/ closing and waking up are enabled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

6 0 7 No No Yes

From

 

To

Description

1   1 indication of opening-closing status change
2   2 indication of wake up (1 x click or periodical)
4   4 indication of device tampering

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Associations in Z-Wave network Security Mode This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network Security Mode. It does not apply to 1st group Lifeline. 0 - none of the groups sent as secure 1 - 2nd group On-Off sent as secure 2 - 3rd group Tamper sent as secure 3 - 2nd and 3rd group sent as secure

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

3 0 3 No No Yes

From

 

To

Description

0   0 none of the groups sent as secure
1   1 2nd group On-Off sent as secure
2   2 3rd group Tamper sent as secure
3   3 2nd and 3rd group sent as secure

Parameter Number

Parameter Size

Parameter Name

Description

30 2 Tamper - alarm cancellation delay Time period after which a tamper alarm will be cancelled. 0-32400- time in seconds .

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 0 32400 No No Yes

From

 

To

Description

0   32400 time in seconds

Parameter Number

Parameter Size

Parameter Name

Description

31 1 Tamper - reporting alarm cancellation Reporting cancellation of tamper alarm to the controller and 3rd association group. 0 - do not send tamper cancellation report 1 - send tamper cancellation report

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No Yes

From

 

To

Description

1   1 send tamper cancellation report
0   0 do not send tamper cancellation report

Parameter Number

Parameter Size

Parameter Name

Description

50 2 Interval of temperature measurements This parameter defines how often the temperature will be measured. The shorter the time, the more frequently the temperature will be measured, but the battery life will shorten. 0 - temperature measurements disabled 5-32400 - time in seconds

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

300 0 32400 No No Yes

From

 

To

Description

0   0 temperature measurements disabled
5   32400 time in seconds

Parameter Number

Parameter Size

Parameter Name

Description

51 2 Temperature reports threshold This parameter defines the change of temperature in comparison with last reported, resulting in temperature report being sent to the main controller. 0 - temperature reports based on threshold disabled 1-300 - temperature threshold (0.1-30C, 0.1C step) NOTE Parameter 51 is active only if parameter 50 is not set to 0. Temperature measurement is performed before sending any report (regardless of parameter no. 50). Excessive reporting can affect battery lifetime. Reporting on the basis of temperature change (parameter no. 51) is recommended.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 0 300 No No Yes

From

 

To

Description

0   0 temperature reports based on threshold disabled
1   300 temperature threshold (0.1-30C, 0.1C step)

Parameter Number

Parameter Size

Parameter Name

Description

52 2 Interval of temperature reports This parameter determines how often the temperature reports will be sent to the main controller (regardless of parameters 50 and 51). 0 - periodic temperature reports disabled 300-32400 - time in seconds

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 32400 No No Yes

From

 

To

Description

0   0 periodic temperature reports disabled
300   32400 time in seconds

Parameter Number

Parameter Size

Parameter Name

Description

53 2 Temperature offset The value to be added to the actual temperature, measured by the sensor (temperature compensation). - 1000–1000 (-100–100C, 0.1C step)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 -1000 1000 No No Yes

From

 

To

Description

-1000   1000 (-100–100C, 0.1C step)

Parameter Number

Parameter Size

Parameter Name

Description

54 1 Temperature alarm reports Temperature alarms reported to the Z-Wave controller. Thresholds are set in parameters 55 and 56. 0 - temperature alarms disabled 1 - high temperature alarm 2 - low temperature alarm 3 - high and low temperature alarms enabled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No Yes

From

 

To

Description

0   0 temperature alarms disabled
1   1 high temperature alarm
2   2 low temperature alarm
3   3 high and low temperature alarms enabled

Parameter Number

Parameter Size

Parameter Name

Description

55 2 High temperature alarm threshold If temperature is higher than set value, overheat notification will be sent and high temperature scene will be triggered (if activated). 1-600 (0.1-60C, 0.1C step)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

350 1 600 No No Yes

From

 

To

Description

1   600 (0.1-60C, 0.1C step)

Parameter Number

Parameter Size

Parameter Name

Description

56 2 Low temperature alarm threshold If temperature is lower than the set value, underheat notification will be sent and low temperature scene will be triggered (if activated). 0-599 (0-59.9C, 0.1C step)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

100 0 599 No No Yes

From

 

To

Description

0   599 (0-59.9C, 0.1C step)