There are over 4377 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Door window state | This parameter allows to set in what state is door window when the magnet is close to the sensor. 0 - closed when magnet near 1 - opened when magnet near | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | Yes |
From |
To |
Description |
|||
0 | 0 | closed when magnet near | |||
1 | 1 | opened when magnet near | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 1 | 2nd association group triggers | Parameter defines events which result in sending on-off commands to devices added to the 2nd association group. These commands are sent alternately to switch the devices on and off. 0 - switch after opening and closing 1 - switch after opening (parameter 12) 2 - switch after closing (parameter 13) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | Yes |
From |
To |
Description |
|||
1 | 1 | switch after opening (parameter 12) | |||
2 | 2 | switch after closing (parameter 13) | |||
0 | 0 | switch after opening and closing | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
12 | 2 | Association for opening - value sent | Value sent to devices in 2nd association group when opening is detected. The value of 0 turns OFF the device, 255 turns it On. In case of associating devices allowing smooth control, values 1-99 allow to set an associated device to a specified level. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
255 | 0 | 255 | No | No | Yes |
From |
To |
Description |
|||
0 | 0 | turns OFF the device | |||
255 | 255 | turns ON the device | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
13 | 2 | Association for closing - value sent | Value sent to devices in 2nd association group when closing is detected The value of 0 turns OFF the device, 255 turns it On. In case of associating devices allowing smooth control, values 1-99 allow to set an associated device to a specified level. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | Yes |
From |
To |
Description |
|||
0 | 0 | turns OFF the device | |||
255 | 255 | turns ON the device | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
14 | 2 | Association for opening - time delay | Time that must elapse from opening to send the command frame to to devices in 2nd association group. 0-32400 - time in seconds | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 32400 | No | No | Yes |
From |
To |
Description |
|||
0 | 32400 | time in seconds | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
15 | 2 | Association for closing - time delay | Time that must elapse from closing to send the command frame to devices in 2nd association group. 0-32400- time in seconds | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 32400 | No | No | Yes |
From |
To |
Description |
|||
0 | 32400 | time in seconds | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Visual LED indications | This parameter defines events indicated by the visual LED indicator. Disabling events might extend battery life. 1 - indication of opening-closing status change 2 - indication of wake up (1 x click or periodical) 4 - indication of device tampering NOTE Parameter 2 values may be combined, e.g. 1+2=3 means that in -dications for opening/ closing and waking up are enabled. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
6 | 0 | 7 | No | No | Yes |
From |
To |
Description |
|||
1 | 1 | indication of opening-closing status change | |||
2 | 2 | indication of wake up (1 x click or periodical) | |||
4 | 4 | indication of device tampering | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Associations in Z-Wave network Security Mode | This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network Security Mode. It does not apply to 1st group Lifeline. 0 - none of the groups sent as secure 1 - 2nd group On-Off sent as secure 2 - 3rd group Tamper sent as secure 3 - 2nd and 3rd group sent as secure | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3 | 0 | 3 | No | No | Yes |
From |
To |
Description |
|||
0 | 0 | none of the groups sent as secure | |||
1 | 1 | 2nd group On-Off sent as secure | |||
2 | 2 | 3rd group Tamper sent as secure | |||
3 | 3 | 2nd and 3rd group sent as secure | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
30 | 2 | Tamper - alarm cancellation delay | Time period after which a tamper alarm will be cancelled. 0-32400- time in seconds . | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 0 | 32400 | No | No | Yes |
From |
To |
Description |
|||
0 | 32400 | time in seconds | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
31 | 1 | Tamper - reporting alarm cancellation | Reporting cancellation of tamper alarm to the controller and 3rd association group. 0 - do not send tamper cancellation report 1 - send tamper cancellation report | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | Yes |
From |
To |
Description |
|||
1 | 1 | send tamper cancellation report | |||
0 | 0 | do not send tamper cancellation report | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
50 | 2 | Interval of temperature measurements | This parameter defines how often the temperature will be measured. The shorter the time, the more frequently the temperature will be measured, but the battery life will shorten. 0 - temperature measurements disabled 5-32400 - time in seconds | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
300 | 0 | 32400 | No | No | Yes |
From |
To |
Description |
|||
0 | 0 | temperature measurements disabled | |||
5 | 32400 | time in seconds | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
51 | 2 | Temperature reports threshold | This parameter defines the change of temperature in comparison with last reported, resulting in temperature report being sent to the main controller. 0 - temperature reports based on threshold disabled 1-300 - temperature threshold (0.1-30C, 0.1C step) NOTE Parameter 51 is active only if parameter 50 is not set to 0. Temperature measurement is performed before sending any report (regardless of parameter no. 50). Excessive reporting can affect battery lifetime. Reporting on the basis of temperature change (parameter no. 51) is recommended. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10 | 0 | 300 | No | No | Yes |
From |
To |
Description |
|||
0 | 0 | temperature reports based on threshold disabled | |||
1 | 300 | temperature threshold (0.1-30C, 0.1C step) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
52 | 2 | Interval of temperature reports | This parameter determines how often the temperature reports will be sent to the main controller (regardless of parameters 50 and 51). 0 - periodic temperature reports disabled 300-32400 - time in seconds | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 32400 | No | No | Yes |
From |
To |
Description |
|||
0 | 0 | periodic temperature reports disabled | |||
300 | 32400 | time in seconds | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
53 | 2 | Temperature offset | The value to be added to the actual temperature, measured by the sensor (temperature compensation). - 1000–1000 (-100–100C, 0.1C step) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | -1000 | 1000 | No | No | Yes |
From |
To |
Description |
|||
-1000 | 1000 | (-100–100C, 0.1C step) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
54 | 1 | Temperature alarm reports | Temperature alarms reported to the Z-Wave controller. Thresholds are set in parameters 55 and 56. 0 - temperature alarms disabled 1 - high temperature alarm 2 - low temperature alarm 3 - high and low temperature alarms enabled. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 3 | No | No | Yes |
From |
To |
Description |
|||
0 | 0 | temperature alarms disabled | |||
1 | 1 | high temperature alarm | |||
2 | 2 | low temperature alarm | |||
3 | 3 | high and low temperature alarms enabled | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
55 | 2 | High temperature alarm threshold | If temperature is higher than set value, overheat notification will be sent and high temperature scene will be triggered (if activated). 1-600 (0.1-60C, 0.1C step) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
350 | 1 | 600 | No | No | Yes |
From |
To |
Description |
|||
1 | 600 | (0.1-60C, 0.1C step) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
56 | 2 | Low temperature alarm threshold | If temperature is lower than the set value, underheat notification will be sent and low temperature scene will be triggered (if activated). 0-599 (0-59.9C, 0.1C step) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
100 | 0 | 599 | No | No | Yes |
From |
To |
Description |
|||
0 | 599 | (0-59.9C, 0.1C step) | |||