Z-Wave Products

There are over 4392 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Multisensor (HKZW-MS01)

Z-Wave Certification Number: ZC10-17045529


Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 MOTION SENSOR’S SENSITIVITY. 1 to 8
(Default)
Level 0 to 8
  0 Disabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 2 MOTION SENSOR’S BLIND TIME (INSENSITIVITY) 1 to 60
(Default)
blink time is 1 to 60

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 ENABLE/DISABLE BASIC COMMAND 0
(Default)
Disable
  1 Enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 BASIC COMMAND VALUE 0
(Default)
Detecting motion: BASIC ON, motion alarm cancellation: BASIC OFF.
  1 Detecting motion: BASIC OFF, motion alarm cancellation: BASIC ON.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

170 1 No.170 SET PARAMETER 171 – 174 TO DEFAULT SETTINGS 85 Set parameter 171,172,173,174 to default settings

Parameter Number

Parameter Size

Parameter Name

Parameter Values

171 4 BATTERY REPORT INTERVAL 5 to 2678400
(Default)
The interval of sending battery report

Parameter Number

Parameter Size

Parameter Name

Parameter Values

172 4 TEMPERATURE REPORT INTERVAL 5 to 2678400
(Default)
The interval of sending temperature report

Parameter Number

Parameter Size

Parameter Name

Parameter Values

173 4 HUMIDITY REPORT INTERVAL 5 to 2678400
(Default)
The interval of sending Humidity report

Parameter Number

Parameter Size

Parameter Name

Parameter Values

174 4 LUMINANCE REPORT INTERVAL 5 to 2678400
(Default)
The interval of sending luminance report

Parameter Number

Parameter Size

Parameter Name

Parameter Values

181 1 BATTERY REPORT THRESHOLD 0 to 100
(Default)
the change in battery level resulting in battery report being sent to the main controller.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

182 1 TEMPERATURE REPORT THRESHOLD 0 reports are not sent
  1 to 255
(Default)
the change in temperature level resulting in temperature report being sent to the main controller.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

183 1 HUMITIDY REPORT THRESHOLD 0 reports are not sent
  1 to 255
(Default)
the change in humidity level resulting in humidity report being sent to the main controller.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

184 2 LUMINANCE REPORT THRESHOLD 0 Reports are not sent
  1 to 65535
(Default)
the change in luminance level resulting in luminance report being sent to the main controller.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

32 1 LEVEL OF LOW BATTERY 10 to 50
(Default)
The low level from 10% to 50%