There are over 4392 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 2 | TIME | 5 to 900 (Default) |
seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | OFF_BEHAVIOUR | 0 | Lamp is switched off and remains so until any new motion event (local or remote) is received. | |
1 to 100 (Default) |
timeout: 1 second (1) to 100 seconds (100) in 1-second resolution | ||||
101 to 200 | timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution | ||||
201 to 209 | timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution | ||||
255 | Lamp is switched off for TIME (cfg 1). It does not wait for a motion event and works normally via current motion evaluation | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | ON_BEHAVIOUR | 0 | Lamp is switched on and remains so until any new motion event (local or remote) is received. It then works normally via current motion evaluation. Notice – during the day, this mode cannot be ended remotely due to motion events not being transmitted – only via local motion sensor if enabled. | |
1 to 100 | timeout: 1 second (1) to 100 seconds (100) in 1-second resolution | ||||
101 to 200 | timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution | ||||
201 to 209 | timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution | ||||
255 (Default) |
Lamp is switched on for TIME (cfg 1). It does not wait for a motion event and works normally via current motion evaluation. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | ON_TIME_OVER | 0 | o additional waiting for motion. | |
1 to 100 | timeout: 1 second (1) to 100 seconds (100) in 1-second resolution | ||||
101 to 200 | timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution | ||||
201 to 209 (Default) |
timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution | ||||
255 | Never stop waiting before motion. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 2 | ON_OFF_BEHAVIOR | 0 | Lamp is switched off and remains so until any new motion event (local or remote) is received. | |
1 to 100 | timeout: 1 second (1) to 100 seconds (100) in 1-second resolution | ||||
101 to 200 | timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution | ||||
201 to 209 (Default) |
timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution | ||||
255 | device ignores ON - OFF sequence and uses OFF behavior | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 2 | OFF_ON_BEHAVIOUR | 0 | Lamp is switched on and remains so until any new motion event (local or remote) is received. It then works normally via current motion evaluation. Notice – during the day, this mode cannot be ended remotely due to motion events not being transmitted – only via local motion sensor if enabled. | |
1 to 100 | timeout: 1 second (1) to 100 seconds (100) in 1-second resolution. | ||||
101 to 200 | timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution | ||||
201 to 209 (Default) |
timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution | ||||
255 | device ignores OFF - ON sequence and uses ON behaviour | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | SEQUENCY_TIME | 10 to 50 | tenth of second | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 2 | MOTION_DISABLE | 0 (Default) |
BASIC SET to Motion endpoint ignored, Motion sensor still enabled | |
1 to 100 | timeout: 1 second (1) to 100 seconds (100) in 1-second resolution | ||||
101 to 200 | timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution | ||||
201 to 209 | timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution | ||||
255 | BASIC SET to Motion endpoint ignored, Motion sensor still disabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 2 | LIGHT | 2000 (Default) |
2000 - is used as daylight ( always night mode) | |
0 | run Learn ambient light sequence (the level is set automatically) | ||||
2 to 1999 | lux | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | DIM | 0 (Default) |
off (dim = basic light completely disabled) | |
1 to 60 | time [minutes] (enabled in night mode, starts after lamp is switched off after motion detection) | ||||
-1 | whole night (dim through the whole night when lamp is off) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 2 | RANGE | 100 to 500 (Default) |
cm | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | BRIGHTNES MEAS INTERVAL | 0 (Default) |
function is off | |
5 to 120 | minutes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | GLOBAL_LIGHT | 1 (Default) |
ON function | |
0 | OFF function | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | SLAVE_MODE | 0 | Normal mode | |
1 | Slave mode without gateway checking | ||||
2 (Default) |
Normal mode with lifeline error signalisation | ||||
3 | Slave mode with gateway checking | ||||
4 | Stupid mode - lamp permanetly on | ||||