Z-Wave Products

There are over 4290 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: IS 140-2 Z-Wave (40111677001)

Z-Wave Certification Number: ZC10-17045540


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 2 TIME 5 to 900
(Default)
seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 2 OFF_BEHAVIOUR 0 Lamp is switched off and remains so until any new motion event (local or remote) is received.
  1 to 100
(Default)
timeout: 1 second (1) to 100 seconds (100) in 1-second resolution
  101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution
  201 to 209 timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution
  255 Lamp is switched off for TIME (cfg 1). It does not wait for a motion event and works normally via current motion evaluation

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 ON_BEHAVIOUR 0 Lamp is switched on and remains so until any new motion event (local or remote) is received. It then works normally via current motion evaluation. Notice – during the day, this mode cannot be ended remotely due to motion events not being transmitted – only via local motion sensor if enabled.
  1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution
  101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution
  201 to 209 timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution
  255
(Default)
Lamp is switched on for TIME (cfg 1). It does not wait for a motion event and works normally via current motion evaluation.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 2 ON_TIME_OVER 0 o additional waiting for motion.
  1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution
  101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution
  201 to 209
(Default)
timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution
  255 Never stop waiting before motion.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 2 ON_OFF_BEHAVIOR 0 Lamp is switched off and remains so until any new motion event (local or remote) is received.
  1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution
  101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution
  201 to 209
(Default)
timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution
  255 device ignores ON - OFF sequence and uses OFF behavior

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 2 OFF_ON_BEHAVIOUR 0 Lamp is switched on and remains so until any new motion event (local or remote) is received. It then works normally via current motion evaluation. Notice – during the day, this mode cannot be ended remotely due to motion events not being transmitted – only via local motion sensor if enabled.
  1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution.
  101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution
  201 to 209
(Default)
timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution
  255 device ignores OFF - ON sequence and uses ON behaviour

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 SEQUENCY_TIME 10 to 50 tenth of second

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 2 MOTION_DISABLE 0
(Default)
BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to relay endpoint, motion sensor still enabled
  1 to 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution
  101 to 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution
  201 to 209 timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution
  255 BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to relay endpoint, motion sensor still disabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 2 LIGHT 2000
(Default)
2000 - is used as daylight ( always night mode)
  0 run Learn ambient light sequence (the level is set automatically)
  2 to 1999 lux

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 SENSITIVITY 2 to 100
(Default)
%

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 GLOBAL_LIGHT 1
(Default)
ON function
  0 OFF function

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 SLAVE_MODE 0 Normal mode
  1 Slave mode without gateway checking
  2
(Default)
Normal mode with lifeline error signalisation
  3 Slave mode with gateway checking
  4 Stupid mode - lamp permanetly on