Z-Wave Products

There are over 4408 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: In-Wall Switch (FT139-A)

Z-Wave Certification Number: ZC10-18015945


Parameter Number

Parameter Size

Parameter Name

Parameter Values

120 1 Configure the external switch mode for S1. 2 3 way switch mode
  0
(Default)
Enter automatic identification mode
  1 2-state switch mode
  3 Momentary push button mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

121 1 Configure the external switch mode for S2. 0
(Default)
Enter automatic identification mode
  1 2-state switch mode
  2 3 way switch mode
  3 Momentary push button mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

122 1 Set the control destination for external switch 1 control the output loads of itself.
  2 control the other nodes
  3
(Default)
control the output loads of itself and other nodes.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Configure the output status after re-power on it. 1 Always on
  0
(Default)
Last status
  2 Always off

Parameter Number

Parameter Size

Parameter Name

Parameter Values

252 1 Lock/unlock configuration parameters 0
(Default)
Unlock
  1 Lock

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 4 Reset the In-Wall Switch 1431655765 Reset to factory default setting and removed from the z-wave network
  0
(Default)
Reset all configuration parameters to factory default setting

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Overheat protection. 0
(Default)
Disable
  1 Enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

80 1 To set which notification would be sent to the associated devices (Group 1) 0 Send Nothing
  1 Send Hail CC
  2 Send Basic Report CC
  3
(Default)
Send Hail CC when using the manual switch to change the load state.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

81 1 To set which notification would be sent to the associated nodes in association group 3 0 Send Nothing
  1
(Default)
Send Basic Set CC

Parameter Number

Parameter Size

Parameter Name

Parameter Values

82 1 To set which notification would be sent to the associated nodes in association group 4 1
(Default)
Send Basic Set CC
  0 Send Nothing

Parameter Number

Parameter Size

Parameter Name

Parameter Values

83 1 Configure the state of LED when it is in 3 modes 0
(Default)
Energy mode. The LED will follow the status (on/off).
  1 Momentary indicate mode. When the state of Switch’s load changed, the LED will follow the status (on/off) of its load, but the LED will turn off after 5 seconds if there is no any switch action.
  2 Night light mode. The LED will remain ON state.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

84 4 Set the ON/OFF time of the LED when it is in Night light mode. 0 to 60 The minute time of OFF
  256 to 316 The hour time of OFF
  65536 to 65596 The minute time of ON
  16777216 to 16777276 The hour time of ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

86 4 Set appointment 1 0 to 60 The minute value of ON time
  65536 to 65543 The day value (Mon to Sun)
  16777216 Enable the setting.
  256 to 316 The hour value of ON time
  16777215 Disable the setting.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

87 4 Set appointment 2 256 to 316 The hour value of ON time
  65536 to 65543 The day value (Mon to Sun)
  16777215 Disable the setting.
  0 to 60 The minute value of ON time
  16777216 Enable the setting.