There are over 4376 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Set priority Association Group number for an Association Source Node | 1 = Association Group 1 (key A = AG#2) 2 = Association Group 2 (key A = AG#1) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 2 | Yes | No | No |
From |
To |
Description |
|||
1 | 2 | See above | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 1 | Send unsolicited Battery Report on Wake Up | 0 = No 1 = To same node as wake up notification 2 = Broadcast to neighbours | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | Yes | No | No |
From |
To |
Description |
|||
0 | 2 | See above | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 1 | Dimming mode | 0 = Continues dimming until “Stop” Command key is pressed 1 = Stops dimming when “Up” or “Down” Command key is released | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | Yes | No | No |
From |
To |
Description |
|||
0 | 1 | See above | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Function of RemSwiid™ Device key A | 0 = Disabled 1 = Basic/Multilevel Switch 2 2 = Control Central Scene 1 3 = Control Scene Activation 1 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 3 | Yes | No | No |
From |
To |
Description |
|||
0 | 3 | See above | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Function of RemSwiid™ Device key B | 0 = Disabled 1 = Basic/Multilevel Switch 3 2 = Control Central Scene 2 3 = Control Scene Activation 2 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 3 | Yes | No | No |
From |
To |
Description |
|||
0 | 3 | See above | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Function of RemSwiid™ Device key C | 0 = Disabled 1 = Basic/Multilevel Switch 4 2 = Control Central Scene 3 3 = Control Scene Activation 3 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 3 | Yes | No | No |
From |
To |
Description |
|||
0 | 3 | See above | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Function of RemSwiid™ Device key D | 0 = Disabled 1 = Basic/Multilevel Switch 5 2 = Control Door Locks 4 3 = Control Scene Activation 4 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 3 | Yes | No | No |
From |
To |
Description |
|||
0 | 3 | See above | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Function of RemSwiid™ Device key E | 0 = Disabled 1 = Basic/Multilevel Switch 6 2 = Control Central Scene 5 3 = Control Scene Activation 5 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 3 | Yes | No | No |
From |
To |
Description |
|||
0 | 3 | See above | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 1 | Function of RemSwiid™ Device key F | 0 = Disabled 1 = Basic/Multilevel Switch 7 2 = Control Central Scene 6 3 = Control Scene Activation 6 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 3 | Yes | No | No |
From |
To |
Description |
|||
0 | 3 | See above | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | Function of RemSwiid™ Device key G | 0 = Disabled 1 = Basic/Multilevel Switch 8 2 = Control Central Scene 7 3 = Control Scene Activation 7 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 3 | Yes | No | No |
From |
To |
Description |
|||
0 | 3 | See above | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 1 | Function of RemSwiid™ Device key H | 0 = Disabled 1 = Basic/Multilevel Switch 9 2 = Control Central Scene 8 3 = Control Scene Activation 8 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 3 | Yes | No | No |
From |
To |
Description |
|||
0 | 3 | See above | |||