There are over 4347 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Enable/Disable LED Indicator | 0 | Open/Close LED Indicator Disabled | |
1 (Default) |
Open/Close LED Indicator Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Configure Open/Close Reports Sent | 0 (Default) |
Reports Closed when Magnet is close | |
1 | Reports Open when Magnet is close | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Switch Between Notification and Binary Sensor Command Classes | 1 | Notification Command Class is Used | |
2 | Binary Sensor Command Class is Used | ||||
0 (Default) |
Both Command Classes are Used | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Enable/Disable Temperature Sensor | 0 (Default) |
Temperature Sensor Disabled | |
1 | Temperature Sensor Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Temperature Offset | 0 to 125 (Default) |
0 - 125 degrees offset | |
-125 to -1 | -125 to -1 degrees offset | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Temperature Units | 0 (Default) |
Temperature is Reported in Fahrenheit | |
1 | emperature is Reported in Celsius | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Group 2 Basic Set Value | 0 | Turn Off Device | |
1 to 99 | Set Device to Value | ||||
255 (Default) |
Turn On Device | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Basic Set Level (Group 4 Opening) | 0 | Turn Off Device | |
1 to 99 | Set Device to Value | ||||
255 (Default) |
Turn On Device | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Basic Set Level (Group 4 Closing) | 0 (Default) |
Turn Off Device | |
1 to 99 | Set Device to Value | ||||
255 | Turn On Device | ||||