There are over 4377 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Thermostat (PWLY-7828-A1)

Z-Wave Certification Number: ZC10-17065620


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Display Units 0 C
  1
(Default)
F

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 OTA (Over The Air) programming error code 0
(Default)
No error
  1 Battery low, reflashing not possible
  2 OTA cancelled before completion
  3 Fragment CRC error
  4 Total image CRC error
  5 External flash error
  6 Fragment received out of order
  7 Invalid firmware or manufacture ID
  8 OTA session not properly initialized
  9 Same image currently running
  10 Time out during OTA download between fragments

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Display always on 0 Display off in C-Wire powered mode
  1
(Default)
Display on in C-Wire powered mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 HVAC Settings 0 1 Stage Conventional
  1
(Default)
2 Stage Conventional
  2 Heat Pump w/ O-Wire
  3 Heat Pump w/ B-Wire
  4 Heat Pump w/ O-Wire & aux heating
  5 Heat Pump w/ B-Wire & aux heating

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 ECO Mode 0
(Default)
Off
  1 On

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Thermostat Default Settings 0
(Default)
No Change
  1 Restore Thermostat Factory Settings (minus z-wave)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Temperature Calibration 0 to 5
(Default)
0 - 5F; 0-2.8C
  251 to 255 (-5)-(-1)F; (-1) - (-2.8)C

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 LED Dimming (If applicable) 0 Low
  1 Medium
  2 High
  3
(Default)
Auto

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Demand Response Mode 0
(Default)
Off
  1 On

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 Swing Setting 0 to 10
(Default)
0 - 10F; 0 - 5.6C
  0

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Differential Setting 0 to 10
(Default)
0 - 10F; 0 - 5.6C