There are over 4377 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Display Units | 0 | C | |
1 (Default) |
F | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | OTA (Over The Air) programming error code | 0 (Default) |
No error | |
1 | Battery low, reflashing not possible | ||||
2 | OTA cancelled before completion | ||||
3 | Fragment CRC error | ||||
4 | Total image CRC error | ||||
5 | External flash error | ||||
6 | Fragment received out of order | ||||
7 | Invalid firmware or manufacture ID | ||||
8 | OTA session not properly initialized | ||||
9 | Same image currently running | ||||
10 | Time out during OTA download between fragments | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | Display always on | 0 | Display off in C-Wire powered mode | |
1 (Default) |
Display on in C-Wire powered mode | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | HVAC Settings | 0 | 1 Stage Conventional | |
1 (Default) |
2 Stage Conventional | ||||
2 | Heat Pump w/ O-Wire | ||||
3 | Heat Pump w/ B-Wire | ||||
4 | Heat Pump w/ O-Wire & aux heating | ||||
5 | Heat Pump w/ B-Wire & aux heating | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | ECO Mode | 0 (Default) |
Off | |
1 | On | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Thermostat Default Settings | 0 (Default) |
No Change | |
1 | Restore Thermostat Factory Settings (minus z-wave) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Temperature Calibration | 0 to 5 (Default) |
0 - 5F; 0-2.8C | |
251 to 255 | (-5)-(-1)F; (-1) - (-2.8)C | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | LED Dimming (If applicable) | 0 | Low | |
1 | Medium | ||||
2 | High | ||||
3 (Default) |
Auto | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Demand Response Mode | 0 (Default) |
Off | |
1 | On | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Swing Setting | 0 to 10 (Default) |
0 - 10F; 0 - 5.6C | |
0 | |||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Differential Setting | 0 to 10 (Default) |
0 - 10F; 0 - 5.6C | |