Z-Wave Products

There are over 4392 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Water Sensor 6 (ZW122-A)

Z-Wave Certification Number: ZC10-17055598


Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 4 Set the alarm time for the Buzzer when the sensor is triggered. 1 to 255 Repeated cycle of Buzzer alarm.
  256 to 65535 the time of Buzzer keeping ON state (MSB)
  65536 to 2147483647
(Default)
The time of Buzzer keeping OFF state

Parameter Number

Parameter Size

Parameter Name

Parameter Values

101 1 To set what unsolicited report would be sent to the Lifeline group. 3
(Default)
Battery Report and Multilevel sensor report for temperature are enabled.
  1 Battery Report is enabled.
  0 Send Nothing
  2 Multilevel sensor report for temperature is enabled.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

111 4 To set the interval time of sending reports in Report group 1 5 to 2678400
(Default)
Available rang is 5 to 2678400 seconds.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

135 1 To set which sensor report can be sent when the water leak event is triggered and if the receiving device is a non-multichannel device. 0 Send nothing
  1
(Default)
Send notification report to association group 1.
  2 Send configuration 0x88 report to association group 2.
  3 Send notification report to association group 1 and Send configuration 0x88 report to association group 2.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

136 1 When the parameter 0x87 is set to 2 or 3, it can get the sensor probes’ status through this configuration value. 0
(Default)
absence of water is triggered by probe 1.
  1 presence of water is triggered by probe 1.
  2 presence of water is triggered by probe 2.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor. 0
(Default)
Disable
  1 Enable.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

201 2 Temperature sensor calibration -128 to 127
(Default)
Available rang is -12.8℃ to 12.7℃.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

252 1 Enable/disable all configuration parameters to be locked 0
(Default)
Disable
  1 Enable.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 4 Reset to factory defaults. 1 Reset all configuration parameters to factory defaults.
  1431655765 Reset the product to factory defaults.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

39 1 Configure the default low battery value. 10 to 50
(Default)
Available rang is 10% to 50%.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

48 1 Enable/disable the sensor report 0
(Default)
Disable
  1 Enable.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

49 4 Set the upper limit value (overheat). 0 Celsius unit
  1 Fahrenheit unit
  65536 to 2147483647
(Default)
Temperature value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

50 4 Set the lower limit value (under heat) 0 Celsius unit
  1 Fahrenheit unit
  65536 to 2147483647
(Default)
Temperature value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

57 2 Set the recover limit value of temperature sensor. 10 to 255 Available rang is 1.0℉ to 25.5℉

Parameter Number

Parameter Size

Parameter Name

Parameter Values

64 1 Set the default unit of the automatic temperature report in parameter 101-103. 1
(Default)
The unit is Fahrenheit.
  0 The unit is Celsius.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 Set the timeout of awake after the Wake Up CC is sent out.. 8 to 127
(Default)
Available rang is 8 to 127 seconds.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

84 1 Get the state of tilt sensor 1 The Water Sensor main unit is in vertical direction.
  0
(Default)
The Water Sensor main unit is in horizontal direction.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

86 1 Enable/ disable the buzzer. 1
(Default)
Enable
  0 Disable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

87 4 To set which sensor is triggered the buzzer will alarm. 16 If the under heat is triggered, the buzzer will alarm
  1 If the Water leak is triggered, the buzzer will alarm.
  2 If the vibration is triggered, the buzzer will alarm.
  4 If the tilt sensor is triggered, the buzzer will alarm.
  32 If the overheat is triggered, the buzzer will alarm.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

88 1 To set which value of the Basic Set will be sent to the associated nodes in association Group 3 when the Sensor probe 1 is triggered. 1 Presence of water, send Basic Set 0xFF, absence of water, send Basic Set 0x00.
  2 Presence of water, send Basic Set 0x00, absence of water, send Basic Set 0xFF.
  0
(Default)
Send nothing

Parameter Number

Parameter Size

Parameter Name

Parameter Values

89 1 To set which value of the Basic Set will be sent to the associated nodes in association Group 4 when the Sensor probe 2 is triggered. 2 Presence of water, send Basic Set 0x00, absence of water, send Basic Set 0xFF.
  0
(Default)
Send nothing.
  1 Presence of water, send Basic Set 0xFF, absence of water, send Basic Set = 0x00.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 2 Report the current power mode and the product state for battery power mode 257 Keep awake for 10 minutes for battery power mode.
  256 Keep sleep state for Battery power mode
  0
(Default)
USB power mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

94 1 To set which power source level is reported via the Battery CC. 0
(Default)
report the USB power level.
  1 report the CR123A battery level.