Z-Wave Products

There are over 4220 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Smart energy plug-in switch (ph-pan16.eu)

Z-Wave Certification Number: ZC10-17055605


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 2 Watt Meter Report Period 0 0: Disable Watt Report
  1 to 32767
(Default)
1~32767:5s~45h

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Manual Switch Report Mode 0 0 : Disable
  1
(Default)
1 : Enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Auto Report after Reset 0 0 : Enable
  1
(Default)
1 : Disable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 2 Adjustable overload 450 to 1450
(Default)
1450*0.01A = 14.5A

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 2 KWH Meter Report Period 0 0: Disable KWh Report
  1 to 32767
(Default)
1~32767:10min~227 days

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 2 Threshold of current for Load caution 10 to 1300
(Default)
1300*0.01A = 13A

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 2 Threshold of KWh for Load caution 1 to 10000
(Default)
10000*1KWh = 1000 KWh

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Restore switch state mode 0 0 : Switch off
  1
(Default)
1 : Last switch state
  2 2 : Switch on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Mode of Switch Off function 0 0: Disable
  1
(Default)
1: Enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 LED indication mode 1
(Default)
1 : Show switch state
  2 2 : Show night mode
  3 3: One flash mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 2 Auto off timer 0
(Default)
0 : Disable auto off function
  1 to 32767 1-0x7FFF : 1s ~ 32767s

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 RF off command mode 0
(Default)
0 : Switch off
  1 1 : Ignore
  2 2 : Switch toggle