There are over 4290 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 2 | Watt Meter Report Period | 1 to 32767 (Default) |
5*720s=3600s=1 hour | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Existence of Endpoint3 | 1 (Default) |
1: Endpoint exist | |
2 | 2: No Endpoint3 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 2 | KWH Meter Report Period | 1 to 32767 (Default) |
6*10min= 1 hour | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Slected End Point | 1 (Default) |
1: Relay1 | |
2 | 2: Relay2 | ||||
3 | 3: Relay1 & Relay2 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Edge or Pulse mode or Edge-Toggle mode | 1 (Default) |
1: Edge mode | |
2 | 2: Pulse mode | ||||
3 | 3: Edge-Toggle mode | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 2 | Threshold of Current for Load Caution | 10 to 750 (Default) |
750*0.01A = 7.5A | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 2 | Threshold of KWH for Load Caution | 1 to 10000 (Default) |
10000*1KWh = 10000KWh | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Restore switch state mode | 0 | 0: Switch off | |
1 (Default) |
1: Last switch state | ||||
2 | 2: Switch on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 2 | Auto off timer | 0 (Default) |
0: Disable auto off function | |
1 to 32767 | 1-0x7FFF: 1s - 32767s | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | RF Switch off command mode | 0 (Default) |
0: Switch off | |
1 | 1: Ignore | ||||
2 | 2: Switch toogle | ||||
3 | 3:Switch on | ||||