There are over 4252 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
151 | 2 | Power Report Value Threshold | 1 to 65535 (Default) |
Number of Watts the appliance needs to go over for the change to be reported | |
0 | Disabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
152 | 2 | Power Report Percentage Threshold | 1 to 255 (Default) |
Percentage in power usage change the appliance needs to go over for the event to be reported | |
0 | Disabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
171 | 4 | Power Report Frequency | 5 to 2678400 (Default) |
Number of seconds | |
0 | Disabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
172 | 4 | Energy Report Frequency | 5 to 2678400 (Default) |
Number of seconds | |
0 | Disabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
173 | 4 | Voltage Report Frequency | 5 to 2678400 | Number of seconds | |
0 (Default) |
Disabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
174 | 4 | Electricity Report Frequency | 5 to 2678400 | Number of seconds | |
0 (Default) |
Disabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Overload Protection | 0 | Disabled | |
1 (Default) |
Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | On/Off Status Recovery After Power Failure | 0 (Default) |
Power Switch remembers the status prior to power outage and turns back to it | |
1 | Power Switch automatically turns ON once power is restored | ||||
2 | Power Switch automatically turns OFF once power is restored | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
24 | 1 | On/Off Status Change Notifications | 0 | Disabled | |
1 (Default) |
Sends notification if status is changed manually or remotely via Z-Wave | ||||
2 | Sends notification ONLY if status is changed manually by pressing and releasing the Z-Wave button on the Power Switch | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
27 | 1 | LED Indicator Control | 0 (Default) |
LED indicator will display power consumption whenever the device is plugged in | |
1 | LED indicator will display the level of power consumption for 5 seconds only whenever the device is turned on or off | ||||