There are over 4377 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Flush Shutter DC (ZMNHOD1)

Z-Wave Certification Number: ZC10-17085744


Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 2 Activate/deactivate functions ALL ON / ALL OFF 255
(Default)
ALL ON active, ALL OFF active
  0 ALL ON is not active, ALL OFF is not active
  1 ALL ON is not active ALL OFF active
  2 ALL ON active ALL OFF is not active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

110 2 Temperature sensor offset settings 32536
(Default)
offset is 0.0C
  1 to 100 value from 0.1 degrees Celsius to 10.0 degrees Celsius is added to actual measured temperature.
  1001 to 1100 value from -0.1 degrees Celsius to -10.0 degrees Celsius is subtracted to actual measured temperature.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

120 1 Temperature sensor reporting 5
(Default)
= 0,5 degrees Celsius
  1 to 127
(Default)
= 0,1 degrees Celsius - 12,7 degrees Celsius, step is 0,1 degrees Celsius

Parameter Number

Parameter Size

Parameter Name

Parameter Values

250 1 Unsecure / Secure Inclusion 0
(Default)
Unsecure Inclusion
  1 Secure Inclusion

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 Power reporting in Watts on power change for Q1 or Q2 10
(Default)
default value
  0 reporting disabled
  1 to 100
(Default)
= 1% - 100% Reporting enabled. Power report is send (push) only when actual power (in Watts) in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 2 Power reporting in Watts by time interval for Q1 or Q2 0
(Default)
reporting disabled
  1 to 32767 = 1 second - 32767 seconds. Reporting enabled, power report is send with

Parameter Number

Parameter Size

Parameter Name

Parameter Values

71 1 Operating modes 0
(Default)
shutter mode
  1 venetian mode (up/down and slate rotation)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

72 2 Slats tilting full turn time 150
(Default)
= 1,5 seconds
  0 tilting time disabled
  1 to 32767
(Default)
= 0,01seconds - 327,67 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

73 1 Slats position 0 Slats return to previously set position only in case of Z-wave control (not valid for limit switch positions)
  1
(Default)
Slats return to previously set position in case of Z-wave control, push-button operation or when the lower limit switch is reached

Parameter Number

Parameter Size

Parameter Name

Parameter Values

74 2 Motor moving up/down time 0
(Default)
moving time disabled (working with limit switches)
  1 to 32767 = 0,1seconds - 3276,7seconds. After that time motor is stopped (relay goes to off state)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

76 1 Motor operation detection 6
(Default)
= 0,6W
  5 to 100
(Default)
= (0,5W - 10W), step is 0,1W.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

78 1 Forced Shutter DC calibration 0
(Default)
default value
  1 start calibration process (when calibration process is finished, completing full cycle - up, down and up, set the parameter 78 (Forced Shutter calibration) value back to 0

Parameter Number

Parameter Size

Parameter Name

Parameter Values

85 1 Power consumption max delay time 8
(Default)
= 800ms
  3 to 50
(Default)
= 0,3seconds - 5seconds (100ms resolution)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

86 1 Power consumption at limit switch delay time 8
(Default)
8 = 800ms
  3 to 50
(Default)
= 0,3seconds - 5seconds (100ms resolution)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

90 1 Time delay for next motor movement 5
(Default)
= 500ms
  1 to 30
(Default)
= 0,1seconds - 3seconds (100ms resolution)