Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Auto Report Battery Time | 0 to 127 (Default) |
The default value is 12. The tick time can setting by the configuration No.20. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | Auto Report Door/Windo w State | 0 to 127 (Default) |
The default value is 12. The tick time can setting by the configuration No.20. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Auto Report Illumination Time | 0 to 127 (Default) |
The default value is 12. The tick time can setting by the configuration No.20. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Auto Report Temperature Time | 0 to 127 (Default) |
The default value is 12. The tick time can setting by the configuration No.20. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Basic Set Level | 0 to 127 (Default) |
equipment 1 to 100 means the light strength. 0 means turn off the light | |
0 | turn off the light | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Auto Report Tick Interval | 0 to 127 (Default) |
The unit is 1 minute,Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Temperature Differential Report | 1 to 127 (Default) |
Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
22 | 1 | Illumination Differential Report | 0 to 99 (Default) |
Enable this function the device will detect every minutes. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | PIR Sensitivity | 0 to 99 (Default) |
PIR sensitivity settings | |
0 | disable the PIR motion | ||||
1 | the lowest sensitivity | ||||
99 | the highest sensitivity | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Light Threshold | 0 to 100 (Default) |
Setting the illumination threshold to turn on the light | |
1 | 1 means darkest | ||||
99 (Default) |
99 means brightest | ||||
100 | 100 means turn off illumination | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Operation Mode | 0 to 127 (Default) |
Setting Operation mode. | |
2 | Bit1: 1 means test mode, 0 means normal mode. | ||||
4 | Bit2: Disable the door/window function.(1:Disable, 0:Enable) | ||||
8 | Bit3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius | ||||
10 | Bit4: Disable the illumination report after event triggered. (1:Disable, 0:Enable) | ||||
20 | Bit5: Disable the temperature report after event triggered. (1:Disable, 0:Enable) | ||||
40 | Bit6: Reserve. | ||||
80 | Bit7: Disable the back key release into test mode. (1:Disable, 0:Enable) | ||||
1 | Bit0: Reserve. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Mult- Sensor Function Switch | 0 to 127 (Default) |
Multisensor function switch | |
1 | Bit0: Disable magnetic integrate illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable) | ||||
2 | Bit1: Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable) | ||||
4 (Default) |
Bit2: Disable magnetic integrate PIR | ||||
8 | Bit3: When Bit2 is 0 (Enable), Are the device and the lighting in the same room? 0: In the same room(Default),1: In the different room | ||||
10 | Bit4: Disable delay 5 seconds to turn off the light, when door/window closed.(1:Disable, 0:Enable) | ||||
20 | Bit5: Disable auto turn off the light, after door/window opened to turn on the light.(1:Disable, 0:Enable) | ||||
40 | Bit6: Reserve. | ||||
80 | Bit7: Reserve. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Customer Function | 0 to 127 (Default) |
Customer function switch | |
1 | Bit0: Reserve. | ||||
2 | Bit1: Enable sending motion OFF report. (0:Disable, 1:Enable) | ||||
4 (Default) |
Bit2: Enable PIR super sensitivity mode. (0:Disable, 1:Enable) | ||||
8 | Bit3: Disable send out BASIC OFF after door closed. (1:Disable,0:Enable) | ||||
10 | Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report. | ||||
20 | Bit5: Disable Multi CC in auto report. (1:Disable, 0:Enable) | ||||
40 | Bit6: Disable to report battery state when the device triggered.(1:Disable, 0:Enable) | ||||
80 | Bit7: Reserve. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | PIR Re- Detect Interval Time | 1 to 127 (Default) |
default tick is 3 (24 seconds). | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Turn Off Light Time | 0 to 127 (Default) |
default tick is 4 (32seconds). | |