There are over 4393 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
100 | 1 | Set parameter 101-103 to default value. | 0 (Default) |
Reset the parameter 101-103 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
101 | 4 | To set which reports need to be sent in Report group 1. | 4 | Send Meter Report of voltage (V) | |
2 | Send Meter Report of wattage (W) | ||||
8 | Send Meter Report of current (A) | ||||
1 | Send Meter Report of energy (kWh) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
102 | 1 | To set which reports need to be sent in Report group 2. | 1 | Send Meter Report of energy (kWh) | |
2 | Send Meter Report of wattage (W) | ||||
4 | Send Meter Report of voltage (V) | ||||
8 | Send Meter Report of current (A) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
103 | 1 | To set which reports need to be sent in Report group 3. | 1 | Send Meter Report of voltage (V) | |
2 | Send Meter Report of current (A) | ||||
4 | Send Meter Report of wattage (W) | ||||
8 | Send Meter Report of energy (kWh) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
110 | 1 | Set parameter 111-113 to default value. | 0 (Default) |
Reset the parameter 111-113 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
111 | 4 | Set the interval of automatic report for Report group 1. | 1 to 2147483647 (Default) |
The range of interval time is 1 to 2147483647. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
112 | 4 | Set the interval of automatic report for Report group 2. | 1 to 2147483647 (Default) |
The range of interval time is 1 to 2147483647. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
113 | 4 | Set the interval of automatic report for Report group 2. | 1 to 2147483647 (Default) |
The range of interval time is 1 to 2147483647. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
120 | 1 | Configure the external switch mode for S1. | 0 (Default) |
Enter automatic identification mode | |
1 | 2-state switch mode | ||||
2 | 3 way switch mode | ||||
3 | Momentary push button mode | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
121 | 1 | Configure the external switch mode for S2. | 0 (Default) |
Enter automatic identification mode | |
1 | 2-state switch mode | ||||
2 | 3 way switch mode | ||||
3 | Momentary push button mode | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
122 | 1 | Set the control destination for external switch | 2 | control the other nodes | |
1 | control the output loads of itself. | ||||
3 (Default) |
control the output loads of itself and other nodes. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Configure the output status after re-power on it. | 1 | Always on | |
0 (Default) |
Last status | ||||
2 | Always off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
252 | 1 | Lock/unlock configuration parameters | 0 (Default) |
Unlock | |
1 | Lock | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
255 | 4 | Reset the In-Wall Switch | 0 (Default) |
Reset all configuration parameters to factory default setting | |
1431655765 | Reset to factory default setting and removed from the z-wave network | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Current Overload Protection. | 1 (Default) |
Enable | |
0 | Disable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Overheat protection. | 0 (Default) |
Disable | |
1 | Enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
80 | 1 | To set which notification would be sent to the associated devices (Group 1) | 0 | Send Nothing | |
1 | Send Hail CC | ||||
2 | Send Basic Report CC | ||||
3 (Default) |
Send Hail CC when using the manual switch to change the load state. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
81 | 1 | To set which notification would be sent to the associated nodes in association group 3 | 0 | Send Nothing | |
1 (Default) |
Send Basic Set CC | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
82 | 1 | To set which notification would be sent to the associated nodes in association group 4 | 0 | Send Nothing | |
1 (Default) |
Send Basic Set CC | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
83 | 1 | Configure the state of LED when it is in 3 modes | 2 | Night light mode. The LED will remain ON state. | |
0 (Default) |
Energy mode. The LED will follow the status (on/off). | ||||
1 | Momentary indicate mode. When the state of Switch’s load changed, the LED will follow the status (on/off) of its load, but the LED will turn off after 5 seconds if there is no any switch action. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
84 | 1 | Set the ON/OFF time of the LED when it is in Night light mode. | 0 to 60 | The minute time of OFF | |
256 to 316 | The hour time of OFF | ||||
65536 to 65596 | The minute time of ON | ||||
16777216 to 16777276 | The hour time of ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
86 | 4 | Set appointment 1 | 65536 to 65543 | The day value (Mon to Sun) | |
16777216 | Enable the setting. | ||||
256 to 316 | The hour value of ON time | ||||
16777215 | Disable the setting. | ||||
0 to 60 | The minute value of ON time | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
87 | 4 | Set appointment 2 | 256 to 316 | The hour value of ON time | |
65536 to 65543 | The day value (Mon to Sun) | ||||
16777215 | Disable the setting. | ||||
0 to 60 | The minute value of ON time | ||||
16777216 | Enable the setting. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
90 | 1 | Enables/disables parameter 91 and 92 below: | 0 (Default) |
Disable | |
1 | Enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
91 | 2 | Set the threshold value of wattage. | 0 to 60000 (Default) |
The thershold value range is 0 to 60000 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
92 | 1 | Set the threshold value of wattage. | 0 to 100 (Default) |
The thershold value range is 0 to 100 | |