Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Schedule type | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 4 | No | No | No |
Value |
Description |
||||
0 | No schedule/Occupancy based schedule | ||||
1 | Every day the same | ||||
2 | 5-2 Schedule | ||||
3 | 5-1-1 Schedule | ||||
4 | Every day individual | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 1 | EM Heat Type | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Electric | ||||
1 | Gas/Oil | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 1 | Fossil Kit Control | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Thermostat | ||||
1 | External | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
12 | 1 | Auto Changeover | ADVANCED PARAMETER SHOULD ONLY BE CHANGED FROM ITS DEFAULT VALUE BY A QUALIFIED HVAC PROFESSIONAL | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Off | ||||
1 | On | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
13 | 1 | Auto Differential | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 5 | No | No | No |
From |
To |
Description |
|||
0 | 5 | degrees of Fahrenheit | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
14 | 1 | High Cool Stage Finish | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | No | ||||
1 | Yes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
15 | 1 | High Heat Stage Finish | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | No | ||||
1 | Yes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
16 | 1 | Aux Heat Droop | 0 = Comfort (1 is not accepted) Integer from 2 to 15 degrees of Fahrenheit from setpoint | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 15 | No | No | No |
From |
To |
Description |
|||
2 | 15 | degrees of Fahrenheit from setpoint | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
17 | 1 | Up Stage Timer Aux Heat | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 15 | No | No | No |
Value |
Description |
||||
0 | Off | ||||
1 | 30 minutes | ||||
2 | 45 minutes | ||||
3 | 60 minutes | ||||
4 | 75 minutes | ||||
5 | 90 minutes | ||||
6 | 2 hours | ||||
7 | 3 hours | ||||
8 | 4 hours | ||||
9 | 5 hours | ||||
10 | 6 hours | ||||
11 | 8 hours | ||||
12 | 10 hours | ||||
13 | 12 hours | ||||
14 | 14 hours | ||||
15 | 16 hours | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
18 | 1 | Balance Point (Compressor Lockout) | 0 = Off integer from 5 to 65 degrees Fahrenheit in only 5 degrees increments. Other values not accepted. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
65 | 0 | 65 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Balance Point Off | |||
5 | 5 | Balance Point 5 degrees Fahrenheit | |||
10 | 10 | Balance Point 10 degrees Fahrenheit | |||
15 | 15 | Balance Point 15 degrees Fahrenheit | |||
20 | 20 | Balance Point 20 degrees Fahrenheit | |||
25 | 25 | Balance Point 25 degrees Fahrenheit | |||
30 | 30 | Balance Point 30 degrees Fahrenheit | |||
35 | 35 | Balance Point 35 degrees Fahrenheit | |||
40 | 40 | Balance Point 40 degrees Fahrenheit | |||
45 | 45 | Balance Point 45 degrees Fahrenheit | |||
50 | 50 | Balance Point 50 degrees Fahrenheit | |||
55 | 55 | Balance Point 55 degrees Fahrenheit | |||
60 | 60 | Balance Point 60 degrees Fahrenheit | |||
65 | 65 | Balance Point 65 degrees Fahrenheit | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
19 | 1 | Aux Heat Lock Out (Aux Heat Outdoor Lockout) | 0 = Off integer from 5 to 65 degrees Fahrenheit in only 5 degrees increments. Other values not accepted. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 65 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Aux Heat Lockout Off | |||
5 | 5 | Aux Heat Lockout 5 degrees Fahrenheit | |||
10 | 10 | Aux Heat Lockout 10 degrees Fahrenheit | |||
15 | 15 | Aux Heat Lockout 15 degrees Fahrenheit | |||
20 | 20 | Aux Heat Lockout 20 degrees Fahrenheit | |||
25 | 25 | Aux Heat Lockout 25 degrees Fahrenheit | |||
30 | 30 | Aux Heat Lockout 30 degrees Fahrenheit | |||
35 | 35 | Aux Heat Lockout 35 degrees Fahrenheit | |||
40 | 40 | Aux Heat Lockout 40 degrees Fahrenheit | |||
45 | 45 | Aux Heat Lockout 45 degrees Fahrenheit | |||
50 | 50 | Aux Heat Lockout 50 degrees Fahrenheit | |||
55 | 55 | Aux Heat Lockout 55 degrees Fahrenheit | |||
60 | 60 | Aux Heat Lockout 60 degrees Fahrenheit | |||
65 | 65 | Aux Heat Lockout 65 degrees Fahrenheit | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Temperature Scale | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Fahrenheit | ||||
1 | Celsius | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
20 | 1 | Cool 1 CPH (Cooling cycle rate stage 1) | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3 | 1 | 6 | No | No | No |
From |
To |
Description |
|||
1 | 6 | Cycle rates per hour | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
21 | 1 | Cool 2 CPH (Cooling cycle rate stage 2) | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3 | 1 | 6 | No | No | No |
From |
To |
Description |
|||
1 | 6 | Cycle rates per hour | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
22 | 1 | Heat 1 CPH (Heating cycle rate stage 1) | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3 | 1 | 12 | No | No | No |
From |
To |
Description |
|||
1 | 12 | Cycle rates per hour | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
23 | 1 | Heat 2 CPH (Heating cycle rate stage 2) | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3 | 1 | 12 | No | No | No |
From |
To |
Description |
|||
1 | 12 | Cycle rates per hour | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
24 | 1 | Aux Heat CPH (Heating cycle rate Auxiliary Heat) | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
9 | 1 | 12 | No | No | No |
From |
To |
Description |
|||
1 | 12 | Cycle rates per hour | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
25 | 1 | EM Heat CPH (Heating cycle rate Emergency Heat) | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
9 | 1 | 12 | No | No | No |
From |
To |
Description |
|||
1 | 12 | Cycle rates per hour | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
26 | 1 | Compressor Protection | 0 = Off Integer from 1-5 minutes | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 0 | 5 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Compressor Protection Off | |||
1 | 5 | Compressor Protection Minutes | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
27 | 1 | Adaptive Intelligent Recovery | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Off | ||||
1 | On | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
28 | 1 | Minimum Cool Temperature | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
50 | 50 | 99 | No | No | No |
From |
To |
Description |
|||
50 | 99 | Degrees Fahrenheit | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
29 | 1 | Maximum Heat Temperature | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
90 | 40 | 90 | No | No | No |
From |
To |
Description |
|||
40 | 90 | Degrees Fahrenheit | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Outdoor Temperature | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | No | ||||
1 | Wired | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
30 | 1 | Air Filters | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
From |
To |
Description |
|||
0 | 2 | Air Filters | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
31 | 1 | Air Filter 1 Reminder | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 19 | No | No | No |
Value |
Description |
||||
0 | Off | ||||
1 | 10 Run time Days | ||||
2 | 20 Run time Days | ||||
3 | 30 Run time Days | ||||
4 | 45 Run time Days | ||||
5 | 60 Run time Days | ||||
6 | 90 Run time Days | ||||
7 | 120 Run time Days | ||||
8 | 150 Run time Days | ||||
9 | 30 Days | ||||
10 | 45 Days | ||||
11 | 60 Days | ||||
12 | 75 Days | ||||
13 | 3 Months | ||||
14 | 4 Months | ||||
15 | 5 Months | ||||
16 | 6 Months | ||||
17 | 9 Months | ||||
18 | 12 Months | ||||
19 | 15 Months | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
32 | 1 | Air Filter 2 Reminder | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 19 | No | No | No |
Value |
Description |
||||
0 | Off | ||||
1 | 10 Run time Days | ||||
2 | 20 Run time Days | ||||
3 | 30 Run time Days | ||||
4 | 45 Run time Days | ||||
5 | 60 Run time Days | ||||
6 | 90 Run time Days | ||||
7 | 120 Run time Days | ||||
8 | 150 Run time Days | ||||
9 | 30 Days | ||||
10 | 45 Days | ||||
11 | 60 Days | ||||
12 | 75 Days | ||||
13 | 3 Months | ||||
14 | 4 Months | ||||
15 | 5 Months | ||||
16 | 6 Months | ||||
17 | 9 Months | ||||
18 | 12 Months | ||||
19 | 15 Months | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
33 | 1 | Humidification Pad Reminder | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | Off | ||||
1 | 6 Calendar Months | ||||
2 | 12 Calendar Months | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
34 | 1 | Dehumidification Filter Reminder | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 12 | No | No | No |
From |
To |
Description |
|||
0 | 12 | Calendar Months | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
35 | 1 | Ventilation Filter Reminder | integer from 0 to 12 months. 0 = Off 3 = 3 Months 6 = 6 Months 9 = 9 Months 12 = 12 Months Other values not accepted. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 12 | No | No | No |
From |
To |
Description |
|||
0 | 0 | No Ventilation Filter Reminder | |||
3 | 3 | Reminder in 3 Months | |||
6 | 6 | Reminder in 6 Months | |||
9 | 9 | Reminder in 9 Months | |||
12 | 12 | Reminder in 12 Months | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
36 | 1 | UV Devices | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
From |
To |
Description |
|||
0 | 2 | UV Devices | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
37 | 1 | UV Bulb 1 Reminder | integer from 0 to 24 months. 0 = Off 6 = 6 Months 12 = 12 Months 24 = 24 Months Other values not accepted. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 24 | No | No | No |
From |
To |
Description |
|||
0 | 0 | UV Bulb 1 Reminder Off | |||
6 | 6 | Reminder in 6 Months | |||
12 | 12 | Reminder in 12 Months | |||
24 | 24 | Reminder in 24 Months | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
38 | 1 | UV Bulb 2 Reminder | integer from 0 to 24 months. 0 = Off 6 = 6 Months 12 = 12 Months 24 = 24 Months Other values not accepted. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 24 | No | No | No |
From |
To |
Description |
|||
0 | 0 | UV Bulb 2 Reminder Off | |||
6 | 6 | Reminder in 6 Months | |||
12 | 12 | Reminder in 12 Months | |||
24 | 24 | Reminder in 24 Months | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
39 | 1 | Idle Brightness | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 5 | No | No | No |
From |
To |
Description |
|||
0 | 5 | Brightness level | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Equipment Type | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 9 | No | No | No |
Value |
Description |
||||
0 | None | ||||
1 | Standard Gas | ||||
2 | High Efficiency Gas | ||||
3 | Oil | ||||
4 | Electric | ||||
5 | Fan Coil | ||||
6 | Air to Air Heat pump | ||||
7 | Geothermal Heat Pump | ||||
8 | Hot Water | ||||
9 | Steam | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
40 | 1 | Clock Format | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | 12 hour | ||||
1 | 24 hour | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
41 | 1 | Daylight Saving | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Off | ||||
1 | On | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
42 | 1 | Temperature Offset | -3 = -3 deg Fahrenheit -2 = -2 deg Fahrenheit -1 = -1 deg Fahrenheit 0 = Off 1 = +1 deg Fahrenheit 2 = +2 deg Fahrenheit 3 = +3 deg Fahrenheit | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | -3 | 3 | No | No | No |
From |
To |
Description |
|||
-3 | 3 | degrees Fahrenheit Offset | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Reversing Valve | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | O/B on Cool | ||||
1 | O/B on Heat | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Cool Stages | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 2 | No | No | No |
From |
To |
Description |
|||
0 | 2 | Stages | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 1 | Heat Stages; AUX/E stages | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 2 | No | No | No |
From |
To |
Description |
|||
0 | 2 | Stages | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | Aux/E Control | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Both Aux and E | ||||
1 | Either Aux/E | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 1 | Aux Heat Type | |||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Electric | ||||
1 | Gas/Oil | ||||