There are over 4121 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Plug (FT145-K19)

Z-Wave Certification Number: ZC10-17095766


Parameter Number

Parameter Size

Parameter Name

Parameter Values

101 4 To set which report would be sent in Report group 1 1 Send Meter Report of Voltage
  2 Send Meter Report of Current
  4 Send Meter Report of Watt
  8 Send Meter Report of kWh

Parameter Number

Parameter Size

Parameter Name

Parameter Values

102 4 To set which report would be sent in Report group 2 1 Send Meter Report of Voltage
  2 Send Meter Report of Current
  4 Send Meter Report of Watt
  8 Send Meter Report of kWh

Parameter Number

Parameter Size

Parameter Name

Parameter Values

103 4 To set which report would be sent in Report group 3 2 Send Meter Report of Current
  4 Send Meter Report of Watt
  8 Send Meter Report of kWh
  1 Send Meter Report of Voltage

Parameter Number

Parameter Size

Parameter Name

Parameter Values

111 4 Set the time interval of sending Report 1 to 2147483647
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

112 4 Set the time interval of sending Report 1 to 2147483647
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

113 4 Set the time interval of sending Report 1 to 2147483647
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Configure the output load status after re-power on 1 Always on
  2 Always off
  0
(Default)
The last status before the power outage.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

200 1 Partner ID 1 to 127 Others
  0
(Default)
Aeon Labs Standard Product

Parameter Number

Parameter Size

Parameter Name

Parameter Values

252 1 Enable/disable Configuration Locked 0
(Default)
Disable
  1 Enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

254 2 Device Tag 0 to 127
(Default)
Device Tag

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 1 Reset the Plug 1 Reset all configuration parameters to default.
  1431655765 Reset the Plug to factory default

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Current Overload Protection. 1
(Default)
Enabled
  0 Disabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

33 4 Set the RGB LED’s color for testing. 65536 to 16711680 Red color value
  256 to 65535 Green color value
  0 to 255
(Default)
Blue color value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

65 4 To set which report would be sent in Report group 1 2 Send Meter Report of Current
  4 Send Meter Report of Watt
  8 Send Meter Report of kWh
  1 Send Meter Report of Voltage

Parameter Number

Parameter Size

Parameter Name

Parameter Values

66 4 To set which report would be sent in Report group 2 1 Send Meter Report of Voltage
  2 Send Meter Report of Current
  4 Send Meter Report of Watt
  8 Send Meter Report of kWh

Parameter Number

Parameter Size

Parameter Name

Parameter Values

80 1 To set which notification would be sent to the associated nodes in association group 1 0
(Default)
Nothing
  1 Hail CC
  2 Basic Report CC

Parameter Number

Parameter Size

Parameter Name

Parameter Values

81 1 Configure the state of LED 0
(Default)
Energy mode. The LED will follow the status (on/off).
  2 Night light mode. The LED will remain the state that is set via the Multilevel Switch Set CC or Color Switch Set CC.
  1 Momentary indicate mode. When the state of Switch’s load changed, The LED will follow the status (on/off) of its load, but the LED will turn off after 5 seconds if there is no any switch action.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

83 4 Configure the RGB value 0 to 255 Blue color value
  256 to 65535 Green color value
  65536 to 16711680
(Default)
Red color value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

84 4 Configure the brightness level of RGB LED 256 to 356 The brightness of Yellow color
  65536 to 65636 The brightness of Green color
  0 to 100 The brightness of Red color

Parameter Number

Parameter Size

Parameter Name

Parameter Values

90 1 Enable/disable the parameter 91 and 92 0
(Default)
Disable
  1 Enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

91 2 Induce an automatic report 0 to 32767
(Default)
The threshold can be set from 0 to 32767 watt.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

92 1 Induce an automatic report 0 to 100
(Default)
The threshold can be set from 0 to 100%.