There are over 4401 interoperable
Group ID | Group Profile Name | Profile | Maximum Nodes | Description | Endpoint ID | Commands |
---|---|---|---|---|---|---|
1 | 5 | Z-Wave Plus Lifeline | 0 | |||
2 | 5 | Linkage group 2 is assigned to the devices status - sending BASIC SET control frame to the associated devices having detected the CO leak. This product will send a “BASIC SET(0xFF)” message to associated group, when press and release the test button(<2s) to check the function; and this CO alarm will also send a “BASIC SET(0x00)” message to associated group, after end of test alarm(<10s). This CO alarm will send a “BASIC SET(0xFF)” message to associated group, when this product is CO alarm (Conforms to EN 50291-1:2010+A1:2012 standard); and this product will also send a “BASIC SET(0x00)” message to associated group, when CO alarm is cleared. | 0 | |||
3 | 5 | Linkage group 3 reports the detection's status to the associated device. | 0 |